51
|
90
Safety Introduction Product Overview
Determining the Pump Assembly Location
Use the following guidelines to determine a location to mount the pump
assembly:
•
The pump assembly must be mounted on a horizontal surface.
•
The surface must withstand the pump assembly operation.
•
Install the pump assembly where it has minimal exposure to excessive dirt,
road debris and heat buildup.
•
The pump is capable of a 1 meter draft of foam concentrate, however, a
gravity feed setup is preferred.
Locating the Pump Assembly Mounting Holes
Locate and drill the holes for the mounting bracket.
•
Use
to determine the hole dimensions for AQUIS 1.5.
•
Use
to determine the hole dimensions for AQUIS 3.0.
•
Use
to determine the hole dimensions for AQUIS 6.0.
Locating the OIT Mounting Holes
Locate and drill the mounting and opening holes for the OIT.
•
Use
to determine the dimensions for the digital OIT opening.
•
Use
to determine the dimensions for the manual OIT opening.
Installing the Pump Assembly
The foam system components are designed to operate as installed on the
mounting bracket (
,
and
). Do not remove the
components from the mounting bracket and install them independently. Doing
so can damage the components, and will void your warranty.
NOTICE
Modifying the equipment
can damage components
and void your warranty.
•
Do not modify the foam
system.
•
Modification
Do not remove the components from the bracket and install them
directly to the apparatus. Doing so will void your warranty.
1. Align the holes in the mounting bracket to the holes that you drilled in
apparatus.
2. Use the appropriate hardware to secure the pump to the apparatus. Refer
and,
to determine the hardware that you
need.