![Waterous AQUIS 1.5 Installation, Operation And Maintenance Instructions Download Page 59](http://html1.mh-extra.com/html/waterous/aquis-1-5/aquis-1-5_installation-operation-and-maintenance-instructions_3658635059.webp)
59
|
64
1
2
1. Drain port
2. Drain plug
Figure 45
5. Allow the oil to drain.
6. Install the drain plug to the pump (
7. Use the hardware that you set aside to secure the pump to the
mounting bracket (
).
Adding Oil
Note:
Only use SAE 30, non-detergent oil.
1. Remove the vented oil cap and set it aside
(
,
,and
2. Use the chart below to determine the oil capacity of your model.
Model
Model
Oil Capacity
Oil Capacity
AQUIS 1.5
AQUIS 1.5
6.1 oz (0.18 L)
AQUIS 3.0
AQUIS 3.0
10.8 oz (0.32 L)
AQUIS 6.0
AQUIS 6.0
18.9 oz (0.56 L)
3.
Add the specified amount of oil into the oil reserve.
4. Use the sight window to determine the oil level in the reserve.
Note:
The oil cap on the AQUIS 3.0 and 6.0 can be used to determine
the oil is at capacity.
5. Install the oil cap to the oil reserve.
Completing the Oil Change
1. Set the circuit breaker to operating position.
2. Install the cover. Refer to: