Dual Tank System Overview—Optional
In addition to the typical setup, you can add additional flexibility by incorporating the dual tank option. Below is a description of the additional components used in
most applications. Contact Waterous for more information.
Component/Accessory
Component/Accessory
Description
Description
1 Dual tank controller
This controller switches the source that supplies concentrate to the pump.
2 Dual tank signal wire
This cable connects the dual tank controller to the control box on the pump.
3 Tank-A sensor cable
This cable connects the tank-A sensor to the control box.
4 Tank-A level sensor
This sensor alerts the operator when the concentrate reaches a predetermined level in tank-A. This sensor is
available in horizontal or vertical mount configurations.
5 Tank-A
This tank is part of the apparatus and holds the foam concentrate.
6 Tank-B sensor cable
This cable connects the tank-B sensor to the control box.
7 Tank-B level sensor
This sensor alerts the operator when the concentrate reaches a predetermined level in tank-B. This sensor is
available in horizontal or vertical mount configurations.
8 Tank-B
This is added to the apparatus to provide a secondary supply of foam concentrate.
9
Tank-B shutoff valve
The tank-B shutoff valve stops the concentrate from flowing into the supply hose.
10 Tank-B supply hose
This hose supplies concentrate between tank-B supply and the electric valve.
11
Tank-A shutoff valve
The tank-A shutoff valve stops the concentrate from flowing into the supply hose.
12 Tank-A supply hose
This hose supplies concentrate between tank-A supply and the electric valve.
13 Tank-A wye with strainer
This fitting is installed in-line with the tank-A supply hose.
14 Tank-B wye with strainer
This fitting is installed in-line with the tank-B supply hose.
15 Tank-A check valve—3/4 or 1 NPT
This check valve is installed in-line with the tank-A supply hose.
16 Tank-B check valve—3/4 or 1 NPT
This check valve is installed in-line with the tank-B supply hose
17 Electric valve
This valve determines which tank supplies the concentrate.
18 Flush system supply hose
Provides a method of flushing the foam system.
19 Flush system wye with strainer
This fitting is installed in-line with the flush system supply hose
20 Flush check valve—3/4 or 1 NPT
This check valve is installed in-line with the flush system supply hose .
21 Concentrate supply hose
This hose connects the electric valve to the pump.
22 Electric valve cable
This cable connects the electric valve to the dual tank controller.
23 Foam pump
The foam pump transfers pressurized concentrate from the supply tank into the injector.
Note:
Tank-B can take the form of a tank installed in the apparatus, or as an external container.