![Waterous AQUIS 1.5 Installation, Operation And Maintenance Instructions Download Page 52](http://html1.mh-extra.com/html/waterous/aquis-1-5/aquis-1-5_installation-operation-and-maintenance-instructions_3658635052.webp)
52
|
64
Operating the Manual OIT
Q-1230286
1. Press ON/OFF button to start or stop system.
2. Set Foam % ratio.
3. Upper (Blue) LED:
Solid on - System standby.
Slow flashing - System injecting.
Fast flashing - Manual mode.
4. Lower (Red) LED:
Flashing - Concentrate in tank low, 2 min to shutdown.
Solid on - No concentrate, system shutdown.
FOAM %
ON/OFF
3
1
2
4
Figure 41
Feature
Feature
Description
Description
1 Foam percent dial This dial adjust the percentage of concentrate
injected into the waterway.
2 Blue LED
The blue LED indicates the modes and status of the
pump operation.
3 Red LED
The red LED indicates the modes and status of the
pump operation.
4 ON/OFF button
The ON/OFF button enables and disables the foam
operation.
Operating in Normal Mode
In normal operating mode, the OIT uses information from the flowmeter and the
FOAM % dial to produce the desired mix.
Starting and Stopping the Pump
1. Press the
(ON/OFF button) to start the pump and begin
injecting concentrate into the waterway.
2. Press the
(ON/OFF button) to stop the pump and end injecting
concentrate into the waterway.
Adjusting the Mix Ratio
Rotate the
(FOAM % dial) to the desired percent of concentrate
in the mix at the nozzle.