OXISWIM MANUAL
P a g e
39 | 45
10.3
Changing from Chlorine to Hydrogen Peroxide
Steps to follow if using liquid chlorine:
Turn off the chlorine dose pump or chlorine generation via the salt chlorinator
1)
Add one drum of Hydrogen Peroxide per 50,000 litres into the pool. If the pool is an
indoor pool, please make sure the room is well ventilated during this process
2)
Remove the chlorine chemical feed tube from the drum. Put the chemical feed tube
into a bucket of water and press the "Fill Operation" button on the dosing pump to
initiate a manual feed. Repeat the "Fill Operation" cycle at least twice. Give the
chemical tube and foot filter/weight a clean while it is in the bucket of water to
ensure chlorine has been removed from any area that will come in contact with
Hydrogen Peroxide
3)
Once step 2 has been completed chemical tube and foot filter/weight can be put into
the Hydrogen Peroxide. Complete two "Fill Operation" cycles to ensure the pump is
primed
4)
Alter the dosage percentage on the hydrogen peroxide/pump to suit the size of your
pool and season as per the chart located in section 6 of the manual. This should be
done on the pH dose pump as well.
5)
After one week, check the Hydrogen Peroxide level and pH and adjust the feed rate
on the dosing pumps if required.
Summary of Contents for OXISWIM
Page 1: ...D U A L S A N I T I S A T I O N Installation and Operation manual Version 1 1 3 December 2022 ...
Page 11: ...OXISWIM MANUAL P a g e 11 45 INSTALLATION AND COMMISSIONING ...
Page 15: ...OXISWIM MANUAL P a g e 15 45 Oxiswim Typical Installation Layout ...
Page 28: ...OXISWIM MANUAL P a g e 28 45 OPERATION AND MAINTENANCE ...