background image

Limitation of Liability of WFA under this 

warranty:

 Where a warranty exists or is implied 

by law, WFA’s liability is limited (to the extent 

that it can be limited) to repair or replacement 

of the faulty Replaceable Element or the unit or 

an equivalent unit. WFA may, in its discretion, 

choose whether it shall repair or replace any unit 

or Replaceable Element or WFA may choose to 

pay to you the cost of replacing the Replaceable 

Element or the unit or the cost of having the unit 

repaired. To the extent permitted by law, WFA 

assumes no liability whatsoever and disclaims all 

liability for direct, indirect or consequential loss, 

or special, general or other damage or expense 

caused by or arising out of:
•   Any failure to install or use the unit in 

accordance with the Manufacturers 

Instructions, the Installation and Owners 

Manual or WFA’s printed instructions; or

•   The purpose for which you are purchasing the 

unit.

You acknowledge that the quality of water 

supplied and your water usage rate and influent 

water pressure may vary seasonally or over a 

period of time. 
In addition to this water characteristics can 

differ if the unit is relocated or the environment 

changes.
You acknowledge that WFA does not know your 

requirements and cannot and does not warrant 

that the unit is fit for the purpose for which you 

intend to use the unit or is appropriate for the 

purpose for which you intend to use the unit. 

WFA does not authorize others to assume any 

obligation on its behalf even if you inform them of 

the purpose for which you intend to use this unit.

WARNING

WFA does not recommend making alterations 

to your existing plumbing to accommodate this 

system. If you wish to modify existing plumbing 

you must comply with AS 3500 and use a licensed 

plumber. 

WARRANTY

CONTINUED

Summary of Contents for K-WFADUOGN

Page 1: ...OwnersManual WaterFiltersAust WFA recommends that a qualified tradesperson installs your WFA DUO system INSTANT HOT AMBIENT FILTERED DISPENSING UNIT MODEL K WFADUOGN...

Page 2: ...fitting mbsp x tube connect locking clip Pressure Limiting Dual Check Valve 350kPa Rubber Washer Locking Nut Filter Head Assembly with mounting bracket 2 locking clips Filter Cartridge Boiler Hose Cla...

Page 3: ...nk for air circulation PERSONAL INJURY This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unl...

Page 4: ...pplied and must be installed Water supply must be microbiologically safe INSTALLATION PRE REQUIREMENTS TYPICAL INSTALLATION Allow a minimum air space of 100mm around the front sides and top of the boi...

Page 5: ...the 35mm hole Do not pull on the tubing INSTALLING THE DUAL FAUCET Secure the dual faucet into position as shown in diagram Chrome plated Metal Flange Mounting Hole 35mm O Ring Rubber Washer Metal Was...

Page 6: ...nit and tube Firmly connect white push lock fitting to boiling unit pull back to ensure it is locked and refit red locking clip Firmly insert the white tube into the push lock fitting pull back to ens...

Page 7: ...bsp x tube connector Pressure Limiting Dual Check Valve 350kPa Locking clip INSTALL FILTER SYSTEM IF INCLUDED REFER INSTALLATION DIAGRAM The filter system should be installed in a convenient location...

Page 8: ...w from the faucet Allow water to flow consistently and evenly from the dual faucet for 2 minutes before turning off the dual faucet hot water tap Turn on water supply Allow water to flow consistently...

Page 9: ...they are repaired before moving onto the next step CONNECT TO POWER SUPPLY Plug power lead into power supply and switch on SETTING THE HOT WATER TEMPERATURE Turn thermostat dial clockwise to the MAX...

Page 10: ...the dual faucet SCALDING DANGER DANGER WARNING IMPORTANT Adesso Futura INSTANT HOT WATER DUO Press down and forward TEST THERMOSTAT SETTING Run the dual faucet hot tap for 1 minute then allow boiler...

Page 11: ...nections are correct Repeat hot water temperature setting procedure as outlined in Step 18 Check that the hose connecting the dual faucet to the boiling tank is not clogged twisted or kinked WATER FLO...

Page 12: ...ECIFICATIONS Capacity 2 875 litres Pressure Requirement 10 125 psi 0 7 8 6 bar non shock Temperature 2 38 C Flow Rate 1 9 litres per minute GENERAL INSTALLATION OPERATION MAINTENANCE REQUIREMENTS Spac...

Page 13: ...ss II a and II b is passed Reduces Cloudiness Reduces Tastes and Odours Decreases Chlorine N A N A N A 3 3 3 3 System tested and Classified against NSF ANSI Standards 42 and 53 for the reduction of St...

Page 14: ...ut not limited to chlorine ozone chloramines and other related components or act of God The unit has been in conditions which do not conform to the recommended design guidelines or has been operated i...

Page 15: ...tions the Installation and Owners Manual or WFA s printed instructions or The purpose for which you are purchasing the unit You acknowledge that the quality of water supplied and your water usage rate...

Page 16: ...78 089 574 489 Unit 1 91 93 Old Pittwater Road Brookvale NSW 2100 PO Box 636 Freshwater NSW 2096 Phone 61 2 9905 6211 Fax 61 2 9905 6255 Email info wfa com au Web www wfa com au For all enquiries cal...

Reviews: