Figure 7 – Gland Assembly Outline and Dimensions
80
WSP-002-080 (Alloy)
WSP-002-081 (Plastic)
Cut away of gland
TRANSDUCER
CABLE
GLAND NUT
GLAND PACKING RING
GLAND PIPE
HULL PLATE
GLAND PIPE FLANGE
LOCK
SCREW
GLAND LOCK NUT
LOCK PLATE
GASKET ABOVE HULL
GASKET BELOW HULL
50 mm Outside diameter of
GLAND PIPE FLANGE
Drawing not to scale
All sizes in millimeters
STEEL WASHER
Cut away of gland
TRANSDUCER
CABLE
WSP-002-082 (Steel)
63.5 mm Outside diameter of
GLAND PIPE FLANGE
Appr
ox. 1
40 mm
HULL
HULL
Gland Assembly Dimensions
Figure 7 shows the physical dimensions of the WASSP Ltd. supplied gland assembly.
UPS Installation and Mounting Dimensions
Figure 8 (over page) shows the physical dimensions of the optional WASSP Ltd.
supplied 230 V AC UPS. The hole centres on the mounting bracket can be used as
a template for installing the mounting bracket and UPS.
If installing the UPS, carefully read the supplied manufacturer’s quick start guide
and install and operate the UPS accordingly:
1)
Install the UPS indoors in a controlled environment where it cannot be ac-
cidentally turned off. Place it in an area with unrestricted airflow around the
unit, away from water, flammable liquids, gasses, corrosives, and conductive
contaminants. Maintain a minimum clearance of 100 mm on each side of the
UPS. Maintain an ambient temperature range of 0°C to 40°C (32°F to 104°F).
2)
Connect equipment to the receptacles at the rear of the UPS: computers
and monitors should be connected to the ORANGE receptacles for battery
back up and surge protection. Other office machines that do not exceed the
capacity of the UPS may be plugged into either of the two BLACK recepta-
cles that provide surge protection only.
3)
Obtain a suitable input power cable with a minimum cross-sectional area of
1 mm2 to connect the UPS to the mains supply socket.
4)
Press and release the ON/OFF / Alarm Silence button to turn on the UPS.
The UPS beeps and the mains indicator lights up (GREEN).
5)
Turn on the connected equipment.