Enter/Exit Programming Mode
80
Wasp WDI7500/WWS750
Decode Negative Image
Enables/disables the ability to decode a negative image for all symbologies.
When this feature is enabled, you will be unable to read normally-printed
labels or programming labels in this manual. Scan the “Disable” barcode
below to return the scanner to its default for this feature.
The reader can also be set to decode both positive and negative codes for
certain 2D codes. See "
2D Normal/Inverse Symbol Control" on page 168
for
information on this feature.
CAUTION
$P,CIPVR00,P(C
R)
Decode Negative Image = Disable
DEFAULT
$P,CIPVR01,P(CR)
Decode Negative Image = Enable
When this feature is enabled, you will be unable to read other pro-
gramming labels in this manual.
Unlike some programming features and options, Decode Negative
Image selections require that you scan only one programming barcode
label. DO NOT scan an ENTER/EXIT barcode prior to scanning a Decode
Negative Image barcode.
Image Capture
Image capture is supported by RS-232 and USB-COM interfaces only. For
information and a list of options for Image Capture, contact Wasp Technical
Support.