Enter/Exit Programming Mode
Product Reference Guide
77
Flash On Time
Specifies the ON time for the indicator LED while in Flash Mode. The select-
able range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 milli-
second increments. See
in “References” for detailed information
on setting this feature.
$CSNFN
Select Flash ON Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE barcode above, then the bar-
code at left followed by the digits from the Alphanu-
meric characters in
representing your desired character(s). End by scan-
ning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
10 = Flash is ON for 1 Second
Flash Off Time
Specifies the OFF time for the indicator LED while in Flash Mode. The select-
able range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 milli-
second increments. See
in “References” for detailed information
on setting this feature.
$CSNFF
Select Flash OFF Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE barcode above, then the bar-
code at left followed by the digits from the Alphanu-
meric characters in
representing your desired character(s). End by scan-
ning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
06 = Flash is OFF for 600ms