Failure 

Code

Description of the Error

Malfunction

Probable Cause

Solution(s)

E 21

Delta Temperature Central 
Heating flow  and Return > 
TSP 82 value °C

Boiler does not work, E21 
error code flashing on the 
screen

> Lack of water on the system
> Pump blockage
> Pump failiure
> Pump harness
> Installation blockage

1-) RESET boiler at first check if problem removed
2-) Check boiler central heating valves are open if they are closed open 
of all 
3-) Check all radiator valves are open if they are closed open of all 
minimum 3 meters of radiator must be open
4-) RESET boiler and check if problem removed
5-) Call for authorised service at first

E 28

Maximum allowed consecu-
tive lock-out reset reached

Usable RESET number 
reached.

Too many consecutive 
lock-out failures (followed by 
reset) due to other possible 
causes

1-) Removing power supply reset will be allowed 
2-) Check the root cause of Error code to solve 
3-) If fault still persists call for authorised service

E 37

Low voltage anomaly

Boiler does not work, E37 
error code flashing on the 
screen

Low voltage < 165 VAC +/- 
5%  on the supply network 
operation mode
OR
During Au-TO calibration 
mode < 182 VAC +/- 5%

1-) Call for Electrical supply network provider
2-) Error will remove if supply voltage > 170 VAC +/- 5% 
3-) If you seen seen this E37 during calibration calibration can not be 
complete unless supply voltage > 188 VAC +/- 5%

E 40

Wrong network frequency 
survey

Boiler does not work, E40 
error code flashing on the 
screen

Wrong frequency survey out 
of tolererance 50 Hz +/- 5% 
on the supply net  work

1-) Call for Electrical supply network provider
2-) Error will remove if supply frquency  50 Hz +/- 5%

E 41

Loose of flame more than 6 
successive times

Boiler does not work, E41 
error code flashing on the 
screen

> Too many domestic heat 
water request in short period 
( 1 min )
> Low gas pressure

1-) Call for authorised service at first

E 42

Buttons anomaly

Boiler does not work, E42 
error code flashing on the 
screen

Wrong parameters settled on 
TsP menu

1-) Call For service

E 43

Opentherm communication 
error

Boiler does not work, E43 
error code flashing on the 
screen after 1 minute of 
communucation error

Opentherm line disconnected 1-) Remove energy from boiler and re energised E43 will be removed 

and boiler & buttons will get back to funcitional
2-) Replace the room unit batteries with the fresh ones and reset from 
room unit 
3-) Check cabeling between boiler and room unit and re connect if any 
disconnection, if connection set up succesfully then connection symbol 
page 37 symbol 19 will be activated on the screen 
4-) Call for authorised service to re connect openterm connection

rE 44

Cumulated intermittent igni-
tion without reaching burner 
ignition. 

Boiler does not work, E44 
error code flashing on the 
screen

> Intermittent contacts on 
harness
> Hammer effect on water 
net 
> Too many request from 
in shotr time from out side 
room units or thermosad 
bridge etc.

1-) Reset & Restart boiler 
2-) Call for authorised service at first

E 62

Calibration request

Boiler does not work, E62 
error code flashing on the 
screen 

> Calibration not done
> Replacing board but not 
service key from the board 
dismantled
> Service key damaged or 
disconnected
> Updating Software ( 
probable)

1-) Call For service

E 72

Delta T heating at ignition not 
occurred

Boiler does not work, E72 
error code flashing on the 
screen 

> FLOW OR RETURN Sensor 
not on position

1-) Call for authorised service at first
2-) Check RETURN and FLOW sensor on position.

E 74

Second CH temperature 
Probe faulty

Boiler does not work, E74 
error code flashing on the 
screen 

> FLOW and LIMIT Sensor
 ( double NTC ) faulty

1-) Call for authorised service at first
2-) Check CH temperature probe ressistance ( double CH ntc probe is 
used as high temperature limit device) according to page 94 at section 
4.29 if its out of tolerance replace double NTC
3-) Check cabeling and connectors between double NTC and board
4-) Reset & Restart boiler

Summary of Contents for LAWA 18

Page 1: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWA PLUS...

Page 2: ...Lawa LawaPlus Enerwa E24 EnerwaPLUSE24...

Page 3: ...2 2 16 Installation at Partially Protected Exteriors 12 2 2 17 Electrical Connections 12 2 2 18 Optional Controls Room Thermostat External Weather Temperature Sensor and Others 13 2 3 HYDRAULIC INSTA...

Page 4: ...under any circumstances during installation use or maintenance operations and device warranty shall also be void Only the authorized Warmhaus Service is authorized to make the electrical connection o...

Page 5: ...r matches Close valves of devices operating with natural gas and your gas meter Immediately evacuate the place with gas odour Natural Gas Emergency Line from your neighbour or another suitable place D...

Page 6: ...lace Wall installation for the combi boiler should be well secured The hanger plate given as standard with the combi should be installed according to the technique to a full or semi full brick wall ac...

Page 7: ...abnormal operations Various alloy layers may be formed during transit of LPG gas in tanks depending on mixture compositions That causes a change in heating power of mixture assigned to the device and...

Page 8: ...er and by using elbows as low as possible At least 1 bar pressurized grid input water should be supplied to ensure adequate domestic hot water Hydrophore should be used if required Figure 10 Flue peri...

Page 9: ...plications Each 45 elbow usage requires to decrease maximum 50 cm from horizontal vertical distance 60 100 Conventional 90 Elbow 153 11 660 600009 It can be used in horizontal and or vertical flue app...

Page 10: ...elbow contacting with the restrictive set Place the External Wall Plate into the flue terminal as seen in Figure 11 12 for grouping the flue output terminal After placing the flue output terminal thr...

Page 11: ...rd Flue Set Elbow 90 b Flue Extension Pipe c Additional 90 Elbow d Standard Flue Set Pipe Figure 16 II Two 90 elbow sample flue installations d a b c a b c d 4 m Figure 15 I Single 90 bended sample fl...

Page 12: ...Hermetic Flue Type fire resistant insulation material is placed between the wall and exhaust gas relief pipe Materials used for manufacturing the combi are resistant against glycol and propylene based...

Page 13: ...sockets and extension cables are not allowed to use 2 2 17 Optional Controls Room Thermostat External Weather Temperature Sensor and Others Room thermostat Outside Temperature Sensor etc control devi...

Page 14: ...of the radiator Combi safety valve relief should be connected to a discharge cone Otherwise safety valve shall be activated and manufacturer shall not be responsible due to water discharge around the...

Page 15: ...s valve radiator and tap water valves If you will shut off the combi for a short period perform below written operations Do not close combi electrical fuse gas valve radiator and tap water valves Leav...

Page 16: ...screens consist of navy blue colored backlight LCD screen 2 buttons Radiator 3 and Hot Tap Water 4 and 2 pcs RESET 2 and MODE 1 pushbuttons RESET It is used for re starting the combi and eliminating t...

Page 17: ...en light turns off At that position you can adjust the temperature between 35 80 C with the Radiator CH temperature adjustment button 3 Temperature value increases when button is rotated clockwise or...

Page 18: ...if the pressure is lower than this value 18 Failure indicator The temperature value displayed on the combi screen has a 3 C tolerance depending on environmental conditions not arising from the combi...

Page 19: ...installation Hold the MODE button for switching on the combi when letter is available on the screen A cycle starts on the screen Release the button when cycle is completed In some cases combi initiall...

Page 20: ...er is seen as the screen screen light turns off your combi is now at STANDBY position Figure 31 Thermostat position Figure 32 Outside weather temperature sensor Figure 33 Outside temperature sensor op...

Page 21: ...zed Service according to your request Air Discharge Function Activating the menu for LAWA PRIWA and ENERWA models Air discharge function can be activated by pressing the RESET button more than 5 secon...

Page 22: ...ermittent contacts or open contacts on harness carefully 3 Check Domestic heating water temperature sensor ressistance 4 Check cabeling and connectors between NTC and board 5 Reset Restart boiler E 13...

Page 23: ...vice at first E 42 Buttons anomaly Boiler does not work E42 error code flashing on the screen Wrong parameters settled on TsP menu 1 Call For service E 43 Opentherm communication error Boiler does not...

Page 24: ...st perform Au To calibration E 78 Max regulation current value reached Boiler does not work E78 error code flashing on the screen Gas inlet pressure Aging or rust on the electrode Recirculation on flu...

Page 25: ...Au To calibration E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabeling disconnections Gas valve failiure 1 Call for authorised servi...

Page 26: ...ration Temporary wind precence 1 If there is strong wind ie wind storm wait until the wind storm stop then keep using the boiler as it is 36 or 48 hours boiler try to remove half power mode by it self...

Page 27: ...ailures occurring due to transportation unloading loading storing external physical Crushing scratches fractures and chemical factors following delivery of the product 6 Damages and failures arising f...

Page 28: ...10 7 28 10 32 5 12 8 Max Domestic Hot Water flow rate t 30 C min 10 5 10 9 10 7 10 9 13 9 13 3 13 9 14 2 Maximum Minimum water pressure bar 10 0 3 10 0 3 10 0 3 10 0 3 Temperature adjustment range oC...

Page 29: ...2ELL I 2H I3P NUMBER OF CHOOSED CONNECTING CONDITIONS Used gas G20 G20 G25 G25 G20 G25 G20 G31 Countries of destination AT BG CH CZ DK EE ES FI GB GR IE IT LT LV NO PT RO SE SI SK DE LU PL RO BE FR NL...

Page 30: ...30 warmhaus com...

Page 31: ...been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject...

Page 32: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWA PLUS Instruction booklet code of Lawa LawaPlus 150 11 606 000004 Revision Date 09 2020...

Reviews: