3.2.10. Shutting Off the Combi
To bring the combi to OFF position while it is in SUMMER position;
To bring the combi to OFF position while it is in WINTER position;
3.2.11. Use with Room Thermostat (Optional)
To bring the combi to OFF position while it is in SUMMER position;
Important: It is compulsory to have two different lines according
to legal regulations being in force regarding electrical installations
in case of using a thermostat On/Off on the Remote Control. It is
not allowed to use any pipe or hose of the combi as electricity or phone
earthing line. That must be ensured prior to making electrical connections
of the combi.
General Utilization Type
• Please consult our authorized services for room thermostats compatible
with Warmhaus combi.
• Do not remove device components during operation.
• Do not position in direct sunlight exposure or near heat sources.
• Manufacturer company shall not be responsible for below given
situations:
a) Faulty installation
b) Making intervention on the device by unauthorized persons
Installation Instruction:
Device installation shall only be performed by the
Warmhaus Authorized Service. The dual cable required for installation is
supplied by the dealer/consumer.
When the MODE button is hold, while screen
light is on after the cycle is completed, letter
seen on the screen, screen light turns off, now
the combi is at OFF position.
When the MODE button is hold while screen
light is on after the cycle is completed, combi
shall pass to SUMMER position.
Then, when the same transaction is repeated,
after cycle is completed a letter is seen as the
screen screen light turns off, your combi is now
at STANDBY position.
Figure 31
Thermostat position
Figure 32
Outside weather temperature sensor
Figure 33
Outside temperature sensor operation curves
150 cm
Min.
30 cm
Room thermostat should be installed at 1,25 and 1,50 m height
from ground and at least 30 cm distance.
At least 30 cm distance should be available from doors and
windows open for air circulation.
Maintenance and Service Life:
Warmhaus room thermostat should not
come into contact with water or excessive humidity. Unless an external
damage
3.2.12. Outside Temperature Sensor Use (Optional)
Outside Temperature Sensor (optional) can be installed in your combi by
our Authorized Service (see: Installation Section; Accessory Connection
Scheme), and you can enable automatic temperature adjustment for
the radiator with immediate responses to outside weather temperature
changes via smart and comfort operation
(Figure 32). Therefore, it maintains an efficient and economic operation
by reducing the radiator water temperature when outside weather
temperature increases and gradually increasing the radiator water
temperature when outside weather temperature decreases and sets
you free from making radiator temperature adjustments. This sensor is
activated when connected independently from the typology or availability
of used thermostat, the relation between output temperature and outside
temperature is defined according to curves given in the graphic below
based on position of button located on the combi panel.
After connecting the Outside Temperature Sensor, (Figure 32) adjustment is
made according to average external weather temperature of your province
with P04 parameter. Our authorized service will make this adjustment
during installation (Figure 33).