Warmhaus LAWA 18 Installation & User Manual Download Page 4

4

warmhaus.com

We congratulate you for preferring the Warmhaus combi to maintain your 
heating and domestic hot water comfort for long years and thank for your 
trust.  Warmhaus combi, manufactured in accordance with European Union 
standards and advanced technology, are also being imported to many 
countries. You can benefit from our Authorized Technical Service network 
having occupational competency certificate for all kinds of ordinary 
maintenance requirements for this product manufactured with rigorous 
studies. Our Authorized Services guarantee protection of your device 
performance as they always provide original spare parts service. Carefully 
read this guide in order to use the combi in an economic, comfortable and 
efficient way and keep as a source of application.

In order to ensure efficient use, we initially recommend you to have the 
installation performed by a certified dealer experienced and competent in 
installation by the local gas authority.

1.1.  GENERAL WARNINGS

Guide Book is an inseparable and integral part of the product and 
should be delivered to the new user when the device is transferred.  The 
aforementioned book should be carefully protected and used as well as be 
applicable when required as it contains important information regarding 
installation.

Radiator and DHW installations should be engineered and 

produced by a competent and certified engineering company in 

accordance with measurements defined based on laws by 
considering legal regulations in force. 

Installation and Maintenance operations should be performed by 
the expert personnel having adequate technical knowledge in 
installations sector and occupational competency certificate in 
accordance with legal regulations in force.  As the result of a false 

installation, dangers may occur which the manufacturer company cannot 
be held responsible for and may damage people, other live beings (animals, 
plants) or commodities. 

 

Natural Gas Installation Project; One of the dealers authorized  

 

  by a gas company located at your city should be preferred for 
performing project and etude studies.

In order to enable use of the combi with LPG tubes or LPG tanks, 
conversation of the combi should be performed by our authorized 
Warmhaus service. Project design and application for LPG use 
should be performed by the company supplying the tank in 

accordance with local and legal rules.

1.2.  GENERAL WARRANTY CONDITIONS

The Manufacturer company shall not have any responsibilities 

within or out of the agreement scope due to failures arising 

from failing to follow legal regulations in force and standards 

and information given in this guide book (and information and 

instructions provided by the manufacturer under any circumstances) 

during installation, use or maintenance operations and device warranty 

shall also be void. 

Only the authorized Warmhaus Service is authorized to make the 
electrical connection of Combi and supplying electricity 
to the combi.

The maintenance and repairs as the result of failure of the product within 
the warranty period due to material, production and installation errors shall 
be performed as free of charge without claiming any workmanship costs 
and spare part payments.

 

This device should only be used for its designed intended 
purposes (to be used in closed-circuit heater 
installation and production of open circuit domestic hot water 

production). All kinds of other uses are not suitable as well as may create a 
potential danger. 

Manufacturer shall not be responsible for damages occurring due 
to interventions, false installation and initial starting performed by 
unauthorized persons and warranty scope shall be void. As the Combi 
is a device having heating system, domestic hot water, natural gas/LPG 
and electrical connections, do not make and have any interventions made 
without the authorized service.

Device maintenance operations should be performed by the 
authorized and expert technical personnel, and 

It is strictly forbidden to try to detect the gas leakage with the 
help of flame. 

This device has been manufactured to be installed in the country 
given on the technical registry label. Performing the installation in 
countries other than the country written on the table may damage 

individuals, animals and commodities.

Connections sealed with bolt paint must not be opened or 
changed by a person who is absolutely expert and not approved 
service. These seals prove that the bolts required for perfect 

and safe operation have not been changed. If the seals are damaged, the 
guarantee of the device will come to an end!
 

Combi boilers bear CE mark in accordance with below given directives:
- Gas Directive 2009/142/EEC
- Efficiency Directive 92/42/EEC
- Electromagnetic compatibility
- Directive 2014130/EU

Please visit the below given web site of Warmhaus for acquiring more 
detailed information regarding legal regulations on installation of gas fired 
heating devices: www.warmhaus.com

Manufacturer:

 WARMHAUS Isıtma ve Soğutma Sistemleri Tic. A.Ş. Bursa 

Organize Sanayi Bölgesi Park Cad. No:10 16140 Nilüfer-Bursa / Türkiye

WARMHAUS

Warmhaus Authorized Technical Service Centres maintain an assurance 
regarding quality and professionalism on that issue. WARMHAUS is not 
responsible for damages arising from repairs, part replacements and 
maintenances performed by third persons and companies and combi 
remains out of the warranty scope under such conditions.

WARMHAUS A.Ş. reserves the right to make all kinds of technical and 
commercial amendments without giving information and rejects all 
responsibilities depending on misspelling.

1.  DEAR WARMHAUS CUSTOMER 

1015 16

Summary of Contents for LAWA 18

Page 1: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWA PLUS...

Page 2: ...Lawa LawaPlus Enerwa E24 EnerwaPLUSE24...

Page 3: ...2 2 16 Installation at Partially Protected Exteriors 12 2 2 17 Electrical Connections 12 2 2 18 Optional Controls Room Thermostat External Weather Temperature Sensor and Others 13 2 3 HYDRAULIC INSTA...

Page 4: ...under any circumstances during installation use or maintenance operations and device warranty shall also be void Only the authorized Warmhaus Service is authorized to make the electrical connection o...

Page 5: ...r matches Close valves of devices operating with natural gas and your gas meter Immediately evacuate the place with gas odour Natural Gas Emergency Line from your neighbour or another suitable place D...

Page 6: ...lace Wall installation for the combi boiler should be well secured The hanger plate given as standard with the combi should be installed according to the technique to a full or semi full brick wall ac...

Page 7: ...abnormal operations Various alloy layers may be formed during transit of LPG gas in tanks depending on mixture compositions That causes a change in heating power of mixture assigned to the device and...

Page 8: ...er and by using elbows as low as possible At least 1 bar pressurized grid input water should be supplied to ensure adequate domestic hot water Hydrophore should be used if required Figure 10 Flue peri...

Page 9: ...plications Each 45 elbow usage requires to decrease maximum 50 cm from horizontal vertical distance 60 100 Conventional 90 Elbow 153 11 660 600009 It can be used in horizontal and or vertical flue app...

Page 10: ...elbow contacting with the restrictive set Place the External Wall Plate into the flue terminal as seen in Figure 11 12 for grouping the flue output terminal After placing the flue output terminal thr...

Page 11: ...rd Flue Set Elbow 90 b Flue Extension Pipe c Additional 90 Elbow d Standard Flue Set Pipe Figure 16 II Two 90 elbow sample flue installations d a b c a b c d 4 m Figure 15 I Single 90 bended sample fl...

Page 12: ...Hermetic Flue Type fire resistant insulation material is placed between the wall and exhaust gas relief pipe Materials used for manufacturing the combi are resistant against glycol and propylene based...

Page 13: ...sockets and extension cables are not allowed to use 2 2 17 Optional Controls Room Thermostat External Weather Temperature Sensor and Others Room thermostat Outside Temperature Sensor etc control devi...

Page 14: ...of the radiator Combi safety valve relief should be connected to a discharge cone Otherwise safety valve shall be activated and manufacturer shall not be responsible due to water discharge around the...

Page 15: ...s valve radiator and tap water valves If you will shut off the combi for a short period perform below written operations Do not close combi electrical fuse gas valve radiator and tap water valves Leav...

Page 16: ...screens consist of navy blue colored backlight LCD screen 2 buttons Radiator 3 and Hot Tap Water 4 and 2 pcs RESET 2 and MODE 1 pushbuttons RESET It is used for re starting the combi and eliminating t...

Page 17: ...en light turns off At that position you can adjust the temperature between 35 80 C with the Radiator CH temperature adjustment button 3 Temperature value increases when button is rotated clockwise or...

Page 18: ...if the pressure is lower than this value 18 Failure indicator The temperature value displayed on the combi screen has a 3 C tolerance depending on environmental conditions not arising from the combi...

Page 19: ...installation Hold the MODE button for switching on the combi when letter is available on the screen A cycle starts on the screen Release the button when cycle is completed In some cases combi initiall...

Page 20: ...er is seen as the screen screen light turns off your combi is now at STANDBY position Figure 31 Thermostat position Figure 32 Outside weather temperature sensor Figure 33 Outside temperature sensor op...

Page 21: ...zed Service according to your request Air Discharge Function Activating the menu for LAWA PRIWA and ENERWA models Air discharge function can be activated by pressing the RESET button more than 5 secon...

Page 22: ...ermittent contacts or open contacts on harness carefully 3 Check Domestic heating water temperature sensor ressistance 4 Check cabeling and connectors between NTC and board 5 Reset Restart boiler E 13...

Page 23: ...vice at first E 42 Buttons anomaly Boiler does not work E42 error code flashing on the screen Wrong parameters settled on TsP menu 1 Call For service E 43 Opentherm communication error Boiler does not...

Page 24: ...st perform Au To calibration E 78 Max regulation current value reached Boiler does not work E78 error code flashing on the screen Gas inlet pressure Aging or rust on the electrode Recirculation on flu...

Page 25: ...Au To calibration E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabeling disconnections Gas valve failiure 1 Call for authorised servi...

Page 26: ...ration Temporary wind precence 1 If there is strong wind ie wind storm wait until the wind storm stop then keep using the boiler as it is 36 or 48 hours boiler try to remove half power mode by it self...

Page 27: ...ailures occurring due to transportation unloading loading storing external physical Crushing scratches fractures and chemical factors following delivery of the product 6 Damages and failures arising f...

Page 28: ...10 7 28 10 32 5 12 8 Max Domestic Hot Water flow rate t 30 C min 10 5 10 9 10 7 10 9 13 9 13 3 13 9 14 2 Maximum Minimum water pressure bar 10 0 3 10 0 3 10 0 3 10 0 3 Temperature adjustment range oC...

Page 29: ...2ELL I 2H I3P NUMBER OF CHOOSED CONNECTING CONDITIONS Used gas G20 G20 G25 G25 G20 G25 G20 G31 Countries of destination AT BG CH CZ DK EE ES FI GB GR IE IT LT LV NO PT RO SE SI SK DE LU PL RO BE FR NL...

Page 30: ...30 warmhaus com...

Page 31: ...been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject...

Page 32: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWA PLUS Instruction booklet code of Lawa LawaPlus 150 11 606 000004 Revision Date 09 2020...