3.2. SELECTION OF ON/OFF/STANDBY AND SUMMER/
WINTER MODES
Use V automat switch for interrupting the electrical connection of combi.
The temperature value when electricity is supplied to the device is the
temperature value of water in the installation.
3.2.1. On/Off/Standby Positions
Use V automat (fuse) switch for shutting ON/OFF the electrical connection
of combi.
3.2.2. Operation at Winter Position
At that position, combi operates both for heating the environment and
providing hot tap water.
3.2.3. Operation at Summer Position
Combi only operates for heating the domestic hot water at that position. In
order to switch to DHW position;
3.2.4. Resetting the Combi (Re-Starting)
In cases that device gives failure/locking errors hold RESET button for
3-4 seconds, and release after completing the cycle on the screen. You can
reset the device and re-start operations.
3.2.5. Shutting OFF the Combi
To bring the combi to OFF position while it is in SUMMER position;
When the combi is started for the first time,
screen displays nG letter and then a number
(for instance 24) indicating kW power of the
device.
and screen light is closed. Now, combi is in
STANDBY position. The temperature value
when electricity is supplied to the device
is the temperature value of water in the
installation.
Then, OFF letter is displayed,
OFF
OFF
Radiator temperature is adjusted with button
(3) and Domestic Hot Water temperature
adjustment is made with button(4) and this
temperature is displayed by indicator (7) on
the screen.
In order to shuton the combi, hold
MODE
button, whereas a circle starts on the screen,
release the button when circle is completed.
In such cases, combi initially gets in the
Radiator position, it’s symbol flashes at left
top corner of screen and existing radiator
installation temperature is displayed on the
screen and then screen light turns off. At
that position, you can adjust the temperature
between 35 – 80 °C with the Radiator (CH)
temperature adjustment button (3).
Temperature value increases when button is
rotated clockwise or decreases when rotated
counter clockwise. The adjusted value shall
be confirmed after flashing for 4-5 seconds
after releasing the button and continues
to display the temperature value in the
installation.
{If you have a ground heating system adjust your combi for
“Low Temperature Operation”, maximum temperature shall be
limited with the Radiator temperature adjustment button (3)
(e.g. maximum 50 °C)}.
At that position, you can adjust the
temperature between 35 – 60 °C with the
domestic hot water temperature adjustment
button (4) whose symbol is displayed. When
DHW button is rotated, while screen light
is on if you rotate (right) clockwise, you
can increase the temperature, and you can
decrease the temperature when rotated
counter clockwise (left).
If you are starting the combi for the first time
hold MODE button, and release the button
after the cycle is completed on the screen,
initially combi switches to radiator position,
it’s symbol will flash on left top corner of
the screen existing radiator installation
temperature shall be indicated on the screen
and screen light will be turned-off.
In order to switch to DHW position, hold
MODE button and release the button after
completion of cycle on the screen. At that
position, symbol flashes at right top corner
of the screen and existing DHW temperature
will be seen on the screen and screen light
will turn off.
A sample utilization error; when E81 or E06
failure codes are displayed on the device
screen, it has passed to failure since no
ignition occurred in your device. In that
case, any of gas line valves connected to the
combi may be closed, combi boiler will be
restarted when closed valve is opened and
RESET button is pressed. If combi is not
started with resetting, please consult our
Authorized Service.