3
The ash level in the ash pan should be checked periodically. The ash pan must never be
permitted to over fill. Under normal operating conditions during the heating season the ash pan
will typically require emptying on a monthly basis. The appliance should never be operated
without the ash pan in position. The ash may be discarded with garden waste or in line with
local waste disposal regulations, after first ensuring that it is sufficiently cool before emptying
the pan. Caution: never attempt to remove the ash pan after the appliance has just
finished operating as it will be extremely hot and injury will result.
The combustion pot should be cleaned on a weekly basis removing any carbon residue.
Vacuuming with a dedicated ash vacuum cleaner is recommended. Failure to clean the
combustion pot as directed may restrict the flow of air within the appliance adversely affecting
its performance.
Description
Model
WS18/WP18
Type
Wood Pellet Boiler
Dimensions (mm)
Width
650
Depth
1170
Height
1135
Dry Weight (kg)
250
Minimum Allowable Draft (mbar)
0.04
Flue Pipe Diameter (mm)
80
Exhaust gas temperature at maximum output (
⁰
C)
170
Exhaust gas temperature at minimum output (
⁰
C)
65
Exhaust gas mass flow at maximum output (
⁰
C)
0.015
Exhaust gas mass flow at maximum output (
⁰
C)
0.005
Electrical Supply
230V Single Phase @50Hz
Maximum Current (Amps)
5
Maximum Wattage
420
Standby Wattage
20
Performance/Efficiency
(kW)/(%)
Maximum Output
18/92.9
Minimum Output
4/90.1
Fuel
Type
Wood Pellets
Quality
ENPlus A1
Maximum Allowable Pressure (bar)
3
Maximum Allowable Flow Temperature (
⁰
C)
80
Water-side resistance
∆
t 10k (mbar)
9
Water-side resistance
∆
t 20k (mbar)
4.2
Water Capacity (Litres)
60
Fuel Hopper Capacity (kg)
120
Boiler Class
Efficiency
5
Emissions
5
Combustion Ventilation
@20
⁰
C for internal Installation
Low Level (mm x mm)
250 x 250
High Level (mm x mm)
250 x 250
Table 1: Product Data