14
Information screen 3 displays a list of values relating to the software used in the appliance as
shown in Figure 17. The most important of these values is the Software Ver. (meaning software
version). The example in Figure 17 displays the Software Ver. as 3.106b. It is beneficial to be
aware of the software version used on the appliance prior to seeking technical support.
The operating mode of the appliance varies through start-up, operation and shut down, and can
be seen changing when viewing information screen 1 (see Figure 15). Further explanation of
each operating mode is given in Table 5.
Mode
Description
Standby
Awaiting heat demand
System Check
Ensuring that the appliance is ready and safe to start
Pre-Load
Loading the combustion pot with pellets
Ignition
Igniting the combustion pot with pellets
Stabilisation
Ensuring that the flame is given time to establish
Powerband
1,2,3,4,5
Output power determined by heat demand
Extinguish
Shut down initiated
Final Clean
Cleaning of combustion pot and heat exchanger
Blocked
Anti-cycling function that activates a time delay before a restart is possible or the combustion door
can be opened
Table 5: Appliance Operating Modes.
Figure 17: Information Screen (3 of 3).