3.6 Technical Data
Article Number
9741970.00
9741970.02
Version
Standard
Magnetic ring
Dosing range [cm³]
5.0
– 54,0
5.0
– 54.0
Weight [kg]
2.56
2.59
Connection P inner thread
G ¼
G ¼
Connection A inner thread
G ¼
G ¼
Connection 2 and 4 inner thread hose
G 1/8 M8
G 1/8 M8
Max. operating pressure [bar]
200
200
Operating pressure material outlet [bar]
80
80
Min. pneumatic operating pressure [bar]
5
5
Max. pneumatic operating pressure [bar]
7
7
Optimum pneumatic operating pressure [bar]
6
6
Operating voltage range [VDC]
Power consumption [A]
Max. load current [A]
Protection type IAW DIN 40050
Display
Article Number
9741970.03
9741970.04
Version
Initiator
Magnetic ring and Proximity
Switch
Dosing range [cm³]
5.0
– 54.0
5.0
– 54.0
Weight [kg]
2.86
2.64
Connection P inner thread
G ¼
G ¼
Connection A inner thread
G ¼
G ¼
Connection 1 inner thread
G 1/8 M8
G 1/8 M5
Max. operating pressure [bar]
200
200
Operating pressure material outlet [bar]
80
80
Min. pneumatic operating pressure [bar]
5
5
Max. pneumatic operating pressure [bar]
7
7
Optimum pneumatic operating pressure [bar]
6
6
Max. switched current [A]
0.2
0.5
Max. switched voltage [V]
10
– 30
12
– 24
Max. switching capacity [W / VA]
-
10 / 12
Protection type IAW DIN 40050
IP 68/67
IP 67
Display
LED
LED