8 Troubleshooting
8.1 General Information
IMPORTANT
First check all supply lines for connection and serviceability.
All below mentioned failures or problems will only be corrected/repaired by a specialist.
In case of serious problems that cannot be resolved, please contact the Walther Systemtechnik GmbH
customer service.
Problem
Possible cause
Action
The valve works but no
lubricating medium is
ejected
Does the supply pump
transport lubricant?
If pump does not work anymore, refer to operating
manual of pump.
Check the ventilating screws in the supply pump
(see operating manual of pump).
Leakage
Check dosing valve
Continuous signal from
sensor
Initiator defective
Replace initiator
Dosing piston not in end
position
Check dosing valve; check setting of dosing
volume
No signal from sensor
Broken cable
Replace cable
Initiator defective
Replace initiator
Loose connector
Check connection
Loose holder
Fix holder
Loose initiator in holder Fasten initiator to the holder
Permanent signal from
proximity switch
Air piston permanently
in initial position
Check dosing valve
Proximity switch
defective
Replace proximity switch
No signal from proximity
switch
Air piston not in initial
position or defective
Check dosing valve
LED defective
LED or sensor defective Exchange cable, replace initiator
Air in system
Air pockets in grease
container.
Air pockets in hoses.
Disconnect supply hoses from dosing valve; let
grease emerge, then re-connect hoses again. Re-
start with max. dosing quantity.