7  Maintenance and Repair 

7.1  General Information  

 

CAUTION 

Before  starting  any  maintenance  or  repair  work,  ensure  that  all  air-operated  tools  are 
depressurized and disconnected from the air supply. 
Disconnect the main power plug.  

Make sure

 the pneumatic / hydraulic system is pressure-less. 

 

 

IMPORTANT 

This chapter does not cover how to repair the device after damage. Repair work should 
only be performed by a specialized technician or the maintenance team or the 
manufacturer. 

7.2  Routine Tasks  

The maintenance intervals below refer to a single-shift operation. If the device is run in a multi-shift operation 
or is operated very often, the maintenance intervals become shorter. Also, additional factors such as 
cleanliness or work surroundings have to be taken into account. 

WHEN 

WHAT 

HOW 

WHO 

Weekly 

Check dosing valve for 

tightness 

visual 

Specialists 

Weekly 

Check all screw and 

fitting connections for 

tightness  

visual  

Specialists 

Monthly  

Check conductors for 

damages 

visual 

Specialists 

 

 

CAUTION 

Check all functions and safety-related parts for readiness after maintenance if finished.  

 

7.3  Cleaning  

 

Only  use  soft  brushes  for  outside  cleaning  of  the  nozzle  tips.  Never  use  metal  tools 
with sharp edges. 

7.4  Spare Parts  

 

IMPORTANT  
Only use original spare parts from the manufacturer! 

Wrong  or  defective  spare  parts  from  other  manufacturers  can  damage  the  device.  If 
other than original spare parts of the manufacturer will be used, all obligations from the 
manufacturer  or  his  sales  partners,  such  as  guarantees,  service  contracts  etc  will  be 

forfeited

 without further notice.

 

 

Summary of Contents for 9741970.0 Series

Page 1: ...9741970 04 Magnet Tape and Proximity Switch 9741970 00 9741970 02 9741970 03 9741970 04 IMPORTANT Please read this Assembly Instruction carefully before unpacking and start of operation with the incom...

Page 2: ...CE TROUBLESHOOTING 7 1 13 WARRANTY AND LIABILITY 8 1 14 COPYRIGHT 8 1 15 QUALIFICATION OF PERSONNEL 8 2 TRANSPORT 9 2 1 PACKAGING 9 2 2 TASKS BEFORE TRANSPORT 9 3 DESCRIPTION OF FUNCTION 9 3 1 PURPOSE...

Page 3: ...ION 9741970 00 20 9 4 1 Spare Parts Drawing Dosing Valve Station 9741970 00 21 9 4 2 Spare Parts List Dosing Valve Station 9741970 00 22 9 5 DIMENSIONED DRAWING DOSING VALVE STATION 9741970 02 23 9 5...

Page 4: ...726 Germersheim Description Dosing Valve Station Article No 9741970 00 02 03 04 We also declare the conformity with other product relevant directives guidelines Mach Direct 2006 42 EU App I Clause 1 1...

Page 5: ...nt 1 1 Symbols for Hazards Directives and Information Symbols are used indicate dangerous situations and specific behavior These symbols are also used in the assembly instructions All warning danger a...

Page 6: ...ng place device and environment are kept in clean and clearly arranged state at regular intervals Rules and regulations regarding the prevention of accidents that apply to the working site must be obs...

Page 7: ...responsible for providing the required personal protective gear All safety devices and installations should be checked at regular intervals 1 10 Correct Use The device must be used under the specified...

Page 8: ...of the pressure control device or the supply pressure without authorization of the manufac turer company Insufficient inspection of device parts subject to wear Improper repairs and use of spare parts...

Page 9: ...ividual parts in order to avoid damages from external impacts or careless on and off loading Depending on type and duration of transport appropriate transport securing devices have to be used The inco...

Page 10: ...front part for proximity switch 9741970 03 Initiator for controlling the dosing piston This special construction increases the process safety The initiator will send an electric signal once the cycle...

Page 11: ...02 Magnetic Ring Key Pos Description 1 Connection grease 2 Ventilation 3 Adjusting sleeve 4 Connection air 5 Magnetic Tape 3 5 3 9741970 03 Initiator Key Pos Description 1 Connection grease 2 Ventila...

Page 12: ...neumatic operating pressure bar 7 7 Optimum pneumatic operating pressure bar 6 6 Operating voltage range VDC Power consumption A Max load current A Protection type IAW DIN 40050 Display Article Number...

Page 13: ...re delivery It may therefore hap pen that some residues from the test media remain in the valve 1 Fill lubricant supply hoses with lubricant before connecting a dosing valve ventilating Then connect s...

Page 14: ...7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 5 Operation 5 1 General Information The partly completed machine may only be operated if the safety related equipment is...

Page 15: ...uption The following has to be observed for a long term interruption of the device No pressure shall be left in system check displays IMPORTANT Please observe the maintenance instructions 6 3 Shutdown...

Page 16: ...is run in a multi shift operation or is operated very often the maintenance intervals become shorter Also additional factors such as cleanliness or work surroundings have to be taken into account WHEN...

Page 17: ...ransport lubricant If pump does not work anymore refer to operating manual of pump Check the ventilating screws in the supply pump see operating manual of pump Leakage Check dosing valve Continuous si...

Page 18: ...Station 9741970 0x Page 18 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 Appendix 9 1 Data Sh...

Page 19: ...ystemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 2 Option Cable Socket for Inductive Sensor Article No 9742369 1...

Page 20: ...lve Station 9741970 0x Page 20 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 4 Dimensioned Dra...

Page 21: ...age 21 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 4 1 Spare Parts Drawing Dosing Valve Stat...

Page 22: ...00 Zylinder Cylinder 1 9742275 00 Ventilstange Valve rod 1 9742276 01 Endst ck En End section 1 9742277 00 Dosierschraube Metering screw 1 9742278 00 Regulierh lse Metering sleeve 1 9742279 00 Druckz...

Page 23: ...alve Station 9741970 0x Page 23 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 5 Dimensioned Dr...

Page 24: ...age 24 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 5 1 Spare Parts Drawing Dosing Valve Stat...

Page 25: ...Cylinder 1 9742275 00 Ventilstange Valve rod 1 9742276 01 Endst ck End section 1 9742277 00 Dosierschraube Metering screw 1 9742278 00 Regulierh lse Metering sleeve 1 9742279 00 Druckzylinder Hydraul...

Page 26: ...alve Station 9741970 0x Page 26 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 6 Dimensioned Dr...

Page 27: ...age 27 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 6 1 Spare Parts Drawing Dosing Valve Stat...

Page 28: ...00 Ventilstange Valve rod 1 9742276 01 Endst ck End section 1 9742277 00 Dosierschraube Metering screw 1 9742278 00 Regulierh lse Metering sleeve 1 9742280 00 Stellring Paar Set collar 1 9742305 00 H...

Page 29: ...alve Station 9741970 0x Page 29 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 7 Dimensioned Dr...

Page 30: ...age 30 of 31 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 9 7 1 Spare Parts Drawing Dosing Valve Stat...

Page 31: ...ing screw 1 9742278 00 Regulierh lse Metering sleeve 1 9742279 00 Druckzylinder Hydraulic cylinder 1 9742280 00 Stellring Paar Set collar 1 9742283 00 Ring Ring 1 9742364 00 Gewindestift Set screw 1 9...

Reviews: