24
25
List of replacement parts PILOT WA 51
PILOT WA 51
V 20 306
Item
Description
Qty.
Art.-No.
1
Air cap nut
1
V 20 335 15 000
2
Round fan cap
1
V 20 336 34 . . 5*
2.1 Wide fan cap, small
1
V 20 336 44 . . 2*
2.2 Wide fan cap, large
1
V 20 336 50 . . 5*
3
Material nozzle
1
V 20 336 23 . . 3*
4
Packing screw
1
V 20 305 04 003
5
Needle seal
1
V 20 305 13 000
6
Housing, complete
1
V 20 306 01 003
7
Lip seal
1
V 09 220 26 000
8
Material needle
1
V 20 306 06 . . 3*
9
O-ring
1
V 09 102 21 001
10
Piston
1
V 20 305 03 004
11
Hexagonal nut
1
V 20 305 07 003
12
Piston spring
1
V 20 305 12 005
13
Spring bushing
1
V 20 305 02 003
14
Hexagonal socket screw
2
V 20 305 08 003
15
Fastening bolt
1
V 20 305 14 003
* Please indicate the required sizes when placing an order for replacement parts.
We recommend that
bold
-face replacement parts (i.e. wear parts) are hold on stock.
Nozzle Set:
The nozzle insert consists of air cap, material
nozzle and material needle.
Art.-No.
V 15 306 02 . . 3
Nozzle sizes optional:
0,3 • 0,5 • 0,8 • 1,0 • 1,2 • 1,5 mm ø
1 General
1.1
Identification of Model Versions
Models:
Automatic Spray Guns PILOT WA 51
Type:
V 20 305 51 (round jet)
V 20 305 01 (wide/flat jet)
Manufacturer:
WALTHER Spritz-und Lackiersysteme GmbH
Kärntner Str. 18-30
D-42327 Wuppertal
Tel.: 00 49 202 / 787-0
Fax: 00 49 202 / 787-2217
www.walther-pilot.de • Email: [email protected]
1.2
Normal Use
The automatic spray gun PILOT WA 51 must be used only for processing sprayable
materials, in particular :
•
lacquers and paints
•
grease, oil and anti-corrosion agents
•
adhesives
•
ceramic glazes
•
stains
If you intend to spray materials that are not listed here, please contact WALTHER
Spritz- und Lackiersysteme GmbH, Wuppertal.
All parts which are in contact with the material are made of corrosion-free stainless
steel.
The sprayable materials must be sprayed only on workpieces or objects.
The temperature of the material to be sprayed must not exceed 80°C.
The model PILOT WA 51 is not a hand-held spray gun and must therefore be
mounted in a suitable bracket.
The term normal use also implies that any and all safety warnings, operational
handling details, etc., as stated in these operating instructions, must be carefully
read, understood and duly complied with.
This equipment complies with the explosion protection requirements of Directive
2014/34/EU (ATEX) for the explosion group, equipment category and temperature
class indicated on the type plate. When using the equipment, the requirements
specified in these Operating Instructions must be observed at all times.
The technical data indicated on the equipment rating plates and the specifications in
the chapter "Technical Data" must be complied with at all times and must not be
exceeded. An overloading of the equipment must be ruled out.
The equipment may be used in potentially explosive atmospheres only with the
authorisation of the relevant supervisory authority.
The relevant supervisory authority or the operator of the equipment are
responsible for determining the explosion hazard (zone classification).