Product Manual WDC400
Wallgate
2014
29
|Revision 3.0
The controller has various function settings that are described in Table 5 on page 32.
A few important settings and their default states are given in Table 4.
Table 4. Important settings
Setting Name
Default State
Description
Exclusivity (Basin
Shower and WC)
Disabled
This prevents more than one outlet
being operated at a time
Water Lockouts
Disabled
See section 8 for more information on
this setting.
IR sensor Inputs:
Disabled, unless factory
set to Enabled
See section 8 for more information on
this setting.
Dual Flush
(Double Press)
Disabled
See section 8 for more information on
this setting.
Date & Time (RTC)
The current date and time must be set
for some unit functions to operate
correctly. The unit will default on
power up to a specific date and time,
however, this date must be modified.
The blinking message
Set Date & Time
appears on a new unit during first
power up or whenever the correct date
and time is lost because of a power
failure. The default date and time is
then applied. The unit has a minimum
backup supply of 48 hours to avoid
immediate loss of the date and time
settings. See section 8 for instructions
on setting the date and time.
Time Slots
All
Default setting is All, which does not
restrict product usage. Refer to section
8.
Hygiene Purge
Off
Refer to section 8
Remote (AUX) Input set
up
I & J - Remote Lockout
K & L - Remote Flush
M & N - Half flush.
The six Remote inputs can be assigned
to operate any of the remote
functions.