Product Manual WDC400
Wallgate
2014
22
|Revision 3.0
4.
Start the
Purge Cycle
by pressing and holding down the
Menu
and
↓
keys
simultaneously for five seconds. Refer to Figure 3 on page 14 for a picture of the
front panel.
The letter
P
is displayed along with the countdown clock.
5.
Make sure that water flows freely from each basin, shower and WC cistern.
To stop the cycle, switch off the electrical supply to the electronic control unit. Resolve any
problems such as blockages before you run the purge cycle again.
The control unit has various function settings that can be enabled or disabled.
The settings are given in section 8 WDC400 Menu Settings.
5.6.2
Lockout function
The
Lockout
function restricts the number of usages for the basin, shower and WC. The
Lockout
feature is disabled by default.
The
Lockout
function restricts usage to:
10 cycles for the basin.
4 cycles for the shower.
4 cycles for the WC.
When the usage exceeds the maximum permitted number, the item is locked from use for a
period of time:
1 hour for basins and showers.
15 minutes for the WC pans.
To reset the unit when the
Lockout
function is activated, do the following steps:
1.
Switch off the power to the control unit for 5 seconds.
2.
Switch on the power to the control unit.
3.
Check that the basin, showers & WC are operating correctly.