Product Manual WDC400
Wallgate
2014
30
|Revision 3.0
The
Lockout
function is used to prevent misuse of the sanitary facilities. The function is used
to limit the number of operations of any valve within a specified time period.
When the
Lockout
function is enabled, the hot and cold basin outlet can be operated for a
maximum of 5 times each (total 10 times) over a 1 hour period, the shower 4 times over a 1
hour period and the WC 4 times over a 15 minute period.
When the maximum permitted number of operations for any valve is exceeded the valve is
locked out (inoperable) for one hour in case of the basin and showers and 15 minutes for
the WC flush valve. This setting can be enabled or disabled and is factory set to
Disabled
.
Refer to Table 5 on page 32 for more information on the
Lockout
function.
You can adjust the period of operation for each function such as the basin, shower and WC.
The WDC400 electronic control unit cannot control the water temperature for basins or
showers.