- 47 -
2070005
System error
Contact service
2080001
System error
Contact service
2080006
System error
Contact service
2080008
System error
Contact service
2080208
System error
Contact service
3000007
Burner temp
sensor
Burner temperature is
missing/invalid
Contact service
3010007
Air temp sensor
Air temperature is missing/invalid
Connect air temperature sensor.
3010202
Air overheat
Air temperature is too high
Check air vent´s and warm air hoses
for blockages.
3020004
Warning
Hot water target should not be set
higher than coolant target
Adjust the hot water target from
settings
3020007
Water temp
sensor
Water temperature is
missing/invalid
Contact service
3020202
Coolant overheat
Coolant temperature is too high
Coolant is not circulating, bleed the air
out of the system, check the coolant
pump.
50001
System error
CAN bus other errors
Contact service
50006
System error
CAN bus timeout error
Contact service
50008
System error
CAN bus busy error
Contact service
7020B
Low voltage
Cannot start, low voltage
Renew/charge the battery
7020C
System error
Cannot start, device locked
Open locking mode from the control
panel, check control panel user
manual.
7020D
System error
Cannot start, enable input not
asserted
Enable wire is missing, connect the
enable wire or set the main power ON
7020E
System error
Cannot start, burner temperature
missing or too high
Powercut during the operation, Wait
that unit cools down and try to start
again.