29
Gas Conversion and Specifications
Gas Regulator
- NAT Gas / LPG / Butane Only.
NOTE: The gas regulator supplied is
convertible between Natural
Gas and LP Gas, but it’s outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn ‘On’ gas supply and appliance.
3.
Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Measure operating pressure at manifold test point
with two burners operating at 'High Flame' setting.
4.
Verify operating pressure remains correct (Re-adjust regulator
if required).
5.
Screw cap nut back onto regulator.
Gas Type Identification Label
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Commissioning
Before leaving the installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3.
Ensure any paint sealed components are re-sealed on completion of adjustments.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning
Pressure Adjusting
Screw
Cap Nut
Summary of Contents for RN8510GE
Page 9: ...7 Dimensions RN L 8510GE GEC Refer to Page 8 for Cook Top Options RN L 8610GE GEC...
Page 10: ...8 Dimensions RN L 8810GE GEC Refer to Page 8 for Cook Top Options...
Page 25: ...23 Wiring Schematic RN L 8510GE RN L 8610GE RN L 8810GE...
Page 26: ...24 Wiring Schematic Wiring Diagram for RN L 8510GE RN L 8610GE RN L 8810GE...
Page 27: ...25 Wiring Schematic RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 28: ...26 Wiring Schematic Wiring Diagram RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 37: ......