30
Gas Conversion and Specifications
Gas Specifications
- Australia:
- New Zealand:
- UK Only:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
- (*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to information in this section for details).
Natural Gas
LP Gas (Propane)
Open Burner
Main Burner Injectors
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw
Natural Gas
LP Gas
Open Burner
Main Burner Injectors
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw
Natural Gas (G20)
Propane (G31)
Open Burner
Main Burner Injectors
Ø 2.30mm
Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
9.5 mbar
26 mbar
Gas Regulator Cap Screw
Summary of Contents for RN8510GE
Page 9: ...7 Dimensions RN L 8510GE GEC Refer to Page 8 for Cook Top Options RN L 8610GE GEC...
Page 10: ...8 Dimensions RN L 8810GE GEC Refer to Page 8 for Cook Top Options...
Page 25: ...23 Wiring Schematic RN L 8510GE RN L 8610GE RN L 8810GE...
Page 26: ...24 Wiring Schematic Wiring Diagram for RN L 8510GE RN L 8610GE RN L 8810GE...
Page 27: ...25 Wiring Schematic RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 28: ...26 Wiring Schematic Wiring Diagram RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 37: ......