4
Specifications
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
*
Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set through the appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas
Conversion’ section for details).
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Heat Input (nett)
Nominal
6.5 kW
5.5 kW
6.5 kW
5.5 kW
Reduced
1.75 kW
1.85 kW
1.75 kW
1.95 kW
Gas Rate (nett)
Nominal
0.69 m
3
/hr 0.58
m
3
/hr
0.51 kg/hr
0.43 kg/hr
Reduced
0.19 m
3
/hr 0.20
m
3
/hr
0.14 kg/hr
0.15 kg/hr
Supply Pressure
20 mbar
30 / 37 mbar
Burner Operating Pressure (*)
9.5 mbar
26 mbar
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas
LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr
21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas
LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr
21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Connection
3
/
4
” B.S.P. Male
Summary of Contents for RN8510GE
Page 9: ...7 Dimensions RN L 8510GE GEC Refer to Page 8 for Cook Top Options RN L 8610GE GEC...
Page 10: ...8 Dimensions RN L 8810GE GEC Refer to Page 8 for Cook Top Options...
Page 25: ...23 Wiring Schematic RN L 8510GE RN L 8610GE RN L 8810GE...
Page 26: ...24 Wiring Schematic Wiring Diagram for RN L 8510GE RN L 8610GE RN L 8810GE...
Page 27: ...25 Wiring Schematic RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 28: ...26 Wiring Schematic Wiring Diagram RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 37: ......