5
Specifications
- All Other Markets:
NOTE:
(*) Measure Burner operating pressure at manifold test point with 2 burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear and 655mm from floor and is reached from beneath appliance. (Refer to
‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas
Town Gas (**)
Input Rate (N.H.G.C.)
- each Open Burner
28MJ/hr 28MJ/hr
- each 300mm Griddle Section
21MJ/hr
21MJ/hr
Supply Pressure
1.13 - 3.40kPa
0.75 - 1.50kPa
Burner Operating Pressure (*)
0.95kPa 0.63
Pa
Gas Connection
See ‘Gas Connection’ information overleaf
LP Gas (Propane)
Butane
Input Rate (N.H.G.C.)
- each Open Burner
28MJ/hr 28MJ/hr
- each 300mm Griddle Section
21MJ/hr
21MJ/hr
Supply Pressure
2.75 - 4.50kPa
2.75 - 4.50kPa
Burner Operating Pressure (*)
2.6kPa 2.6kPa
Gas Connection
See ‘Gas Connection’ information overleaf
Summary of Contents for RN8510GE
Page 9: ...7 Dimensions RN L 8510GE GEC Refer to Page 8 for Cook Top Options RN L 8610GE GEC...
Page 10: ...8 Dimensions RN L 8810GE GEC Refer to Page 8 for Cook Top Options...
Page 25: ...23 Wiring Schematic RN L 8510GE RN L 8610GE RN L 8810GE...
Page 26: ...24 Wiring Schematic Wiring Diagram for RN L 8510GE RN L 8610GE RN L 8810GE...
Page 27: ...25 Wiring Schematic RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 28: ...26 Wiring Schematic Wiring Diagram RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 37: ......