31
Gas Conversion and Specifications
- All Other Markets:
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to information in this section for further details.
Natural Gas
Town Gas (**)
Open Burner
Main Burner
Ø 2.45mm
Ø 4.50mm
Pilot Burner ('PF' Option Only)
0.30 0.60
Griddle
Main Burner
Ø 2.10mm
Ø 3.40mm
Pilot Burner
0.35 0.60
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
1.13 - 3-4 kPa
0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa
0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner Operating
Pressure specified).
LP Gas (Propane)
Butane
Open Burner
Main Burner
Ø 1.50mm
Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.20 0.20
Griddle
Main Burner
Ø 1.30mm
Ø 1.20mm
Pilot Burner
0.23 0.23
Burner Aeration Setting
Fully open
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Regulator Cap Screw
Summary of Contents for RN8510GE
Page 9: ...7 Dimensions RN L 8510GE GEC Refer to Page 8 for Cook Top Options RN L 8610GE GEC...
Page 10: ...8 Dimensions RN L 8810GE GEC Refer to Page 8 for Cook Top Options...
Page 25: ...23 Wiring Schematic RN L 8510GE RN L 8610GE RN L 8810GE...
Page 26: ...24 Wiring Schematic Wiring Diagram for RN L 8510GE RN L 8610GE RN L 8810GE...
Page 27: ...25 Wiring Schematic RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 28: ...26 Wiring Schematic Wiring Diagram RN L 8510GEC RN L 8610GEC RN L 8810GEC...
Page 37: ......