background image

Summary of Contents for 66592143300

Page 1: ...ona 18 C6mo trasladar la estufa 18 19 Para obtener servicio Contratapa Hacedo facilitara la instalaci6n Io ayudara en el futuro si tiene dguna pregunta Io ayudara si tiene un inspecci6n el6ctrica Si tiene alguna pregunta o necesita servicio Ilame a su tienda o centro de servicio Sears Cuando Ilame necesitara tener el nL_mero de modelo y el m3mero de serie de la estufa Part No 9758666 Parte No 9758...

Page 2: ...fety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A or with local codes When this range is installed in a mobile home it must be secured to the floor during transit Any method of securing the range is adequate as long as it conforms to the standards listed above Four wire power supply cord or cable must be used i...

Page 3: ...porte antivuelco que viene con la estufa ver la P_gina 9 y la hoia de instrucciones plantilla del soporte antivuelco _ _ 18 rain vertical clearance between overhead side cabinet to countertop both sides espacio vertical minimo de 18 entre el gabinete superior y e mostrador a ambos lados 4 rain horizontal spacing to side wall or other combustible material above coektop both sides 4 de espacio minim...

Page 4: ... 5g amp fused on both sides of the line A time delay fuse or circuit breaker is recommended Local codes may permit the use of a U L listed 250 volt range power supply cord pigtail of at least BO amp This cord matches a three wire receptacle of NEMA Type 10 50R Connectors on the appliance end must be provided at the point the power supply cord enters the appliance The range can be connected directl...

Page 5: ... conductores de cobre con terminales anulares o terminales de horquilla con los extremos hacia arriba con una clavija de contacto Tipo NEMA 14 50P en el extremo del suministro electrico El cuarto conductor de tierra debe identificarse por medio de una cubierta verde o verde amarilla y el conductor neutro por una cubierta blanca El cordon debe ser Tipo SRD o SRDT con una abrazadera de anclaje aprob...

Page 6: ...stimiento del piso 10 Electrical connection Grounding instructions This range must be grounded in the event of malfunction or breakdown grounding wiii reduce the risk of electric shock by providing a path of least resistance for electric current if using a power supply cord the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local code...

Page 7: ...range frame_ Save the grounddink screw Bend the groun link away from the range so that it does not contact the range See Figure 1 8 Connect the green ground wire from power supply cord to the range using the ground link screw The ground wire must be attached first and must not contact any other terminal See Figure 2 9 Use a 1 4 nut driver and remove the hex washer head screws from the terminal blo...

Page 8: ...ire under the screw clamp at the bottom of the center position terminal connector Insert the other two wires lines 1 and 2 under the other two screw clamps Securely tighten the hex washer head screws to 90 in Ibs minimum torque to make proper electrical connection See Figure 3 10 Tighten the locking ring of the conduit connector _ 11 Replace the terminal block cover 14 Conexi6n el6etrica de cuatro...

Page 9: ... the cooktop elements Push in 12 oo and turn each surface unit control knob to Hi position Check the operation of the cooktop elements and indicator lights Verifique el funcionamiento de los elementos de la superficie de estufa empuje y gire cada una de las perillas de control de la unidad de superficie hasta la posicion Hi Verifique el funcionamiento de los elementos de la superficie de estufa y ...

Page 10: ...s instrucciones puede ocasionar la muerte o quemaduras graves en niSos y adumtos When moving range slide range onto cardboard or hardboard to prevent damaging the floor covering If moving the range is necessary for cleaning or maintenance 1 Unplug range or disconnect power 2 Slide range forward to complete cleaning or maintenance Cuando traslade la estufa deslice la estufa sobre carton o lamina de...

Page 11: ...sa de las principales marcas Uame Uas24 horas deUdia bs 7 dias de Ua semana 1 800 4 MYoHOME 1 800 469 4663 Para las reparaciones y piezas de reemplazo que usted necesita Uame de 7 a m a 7 p m bs 7 dias de Ua semana 1 800 366 PART 1 800 366 7278 Para Ioealizar un Centro de Piezas de Reempiazo y Reparaeiones Sears en su area Uame Uas24 horas deUdia bs 7 dias de Ua semana 1 800 488 1222 Para informac...

Reviews: