![WAGO 767-5201 Manual Download Page 69](http://html1.mh-extra.com/html/wago/767-5201/767-5201_manual_3292618069.webp)
WAGO-SPEEDWAY 767
Parameterizing
69
767-5201 TTL Incremental/SSI Encoder
Manual
Version 1.1.0
Table 40: Overview of adjustable parameters for the SSI encoder
Parameter
Description:
Alarmbit evaluation
Select whether the SSI encoder outputs an alarm bit. This alarm bit is
evaluated by the module and forwarded as a diagnostic message:
Checkbox unselected:*
No alarm bit is output.
Checkbox selected:
An alarm bit is output.
Alarm bit
This field indicates the status of the alarm bit detected, if alarm bit
evaluation has been selected.
Default setting: inactive
* Factory default setting
Pos: 30.15 /D okumentati on allgemei n/Gli ederungsel emente/---Seitenwechsel--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1