Pos: 30.9 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/I/O-M odule/Parametri erung 767- 5201, - 5202 Gl obal e Di agnosen @ 14\mod_1362395185384_21.docx @ 113580 @ @ 1
Table 36: Information about existing module diagnostics
Global Diagnostics
Diagnostics
Description:
Low voltage U
LS
Disabling the outputs
If there is an undervoltage of U
A
and/or U
LS
, the
module outputs are disabled. This can place machine
components in a dangerous condition, and personnel
and machine may be put in danger.
If an undervoltage of the logic and sensor supply (U
LS
) of < 18 V occurs
on the module, the outputs are disabled and a corresponding diagnostic
is transmitted to the fieldbus coupler.
The F-LED of the module illuminates.
If the logic and sensor supply (U
LS
) is redirected, it can lead to
malfunctions in downstream modules.
Switching Threshold
The switching threshold is typically 17 V.
Low voltage U
A
Disabling the outputs
If there is an undervoltage of U
A
and/or U
LS
, the
module outputs are disabled. This can place machine
components in a dangerous condition, and personnel
and machine may be put in danger.
If an undervoltage of the actuator supply (U
A
) of < 18 V occurs on the
module, the outputs are disabled and a corresponding diagnostic is
transmitted to the fieldbus coupler.
The F-LED of the module illuminates. If the actuator supply (U
A
) is
redirected, it can lead to malfunctions in the downstream modules.
Switching Threshold
The switching threshold is typically 17 V.
Pos: 30.10 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/I/O-Module/Parametrier ung Global e Di agnosen Kurzschl uss/Überlast und U nterbr echung Fel dversorgung @ 8\mod_1278394655719_21.docx @ 59061 @ @ 1
Short circuit/ overload
encoder supply
The module has detected a short circuit or overload of the encoder
supply (only possible when field supply is switched on).
Pos: 30.11 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/I/O-Module/Parametrier ung Kanaldi agnosen Ü bertemper atur @ 7\mod_1268294869501_21.docx @ 52378 @ @ 1
Table 37: Information about existing channel diagnostics
Channel Diagnostics
Diagnostics
Description
Overtemperature
The module has identified overheating on the corresponding channel
(1 – 8) (only enabled when the actuator output is switched on).
Pos: 30.12 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/Sicherheitshinweise/Hinweis/Hi nweis: U nterbrechung S-BU S 48er @ 8\mod_1278393489593_21.docx @ 59044 @ @ 1