WAGO-I/O-SYSTEM 750
Device Description
23
750-494 3-Phase Power Measurement Module
Manual
Version 1.2.0
Pos: 47 /All e Seri en (Allgemei ne Module)/Ü berschriften/Ebene 2/Technische D aten - Ü berschrift 2 @ 3\mod_1232967587687_21.docx @ 26924 @ 2 @ 1
3.6
Technical Data
Pos: 48.1 /Serie 750 (WAGO-I/O-SYST EM)/Ger ätebeschrei bung/T echnische Daten/Anal ogeing angskl emmen/T echnische D aten 750-0494 @ 13\mod_1354714530947_21.docx @ 107410 @ 33333 @ 1
3.6.1
Dimensions and Weight
Table 8: Technical Data
‒
Dimensions and Weight
Width
12 mm
Height (from upper edge of carrier rail) 64 mm
Length
100 mm
Weight
48 g
3.6.2
Voltage Supply
Table 9: Technical Data
‒
Voltage Supply
Voltage
5 V DC
(system voltage via internal bus)
Current consumption max. (internal)
100 mA
3.6.3
Measuring Inputs
Table 10: Technical Data
‒
Measuring Inputs
Number of inputs
6 (3 voltage measuring inputs, 3 current
measuring inputs)
Input voltage max.
Input resistance typ.
Phase-to-phase voltage Lx-Ly: 480
VAC,
phase voltage Lx-N: 277 VAC / DC
1072 kΩ
Input current max.
Input resistance typ.
1 A for 750-494 and /025-000,
5 A for 750-494/xxx-001
22 mΩ for 750
-494 and /025-000,
5 mΩ for 750
-494/xxx-001
Frequency range
• F
requency of supply network
45 … 65 Hz
• A
nalysis of harmonics
0 … 3300 Hz
Max. frequency
15.9 kHz
Signal form
Any periodic signal (considering the
max. operating frequency)
Category of overvoltage
III
Nominal voltage spike
4 kV
Degree of contamination
2