8-4
OM EZ38 us 1.1 * ez38b800.fm
8
8.5
Troubleshooting the air conditioning
8.6
Malfunctions of attachments
No malfunctions specified.
Malfunction/sign
Possible cause
Remedy
See
Fan does not run
Malfunctioning fuse
Check the fuse
Electrical error
Have the error repaired by a
Wacker Neuson service center
--
Reduced or no heat dissipation
capacity
Very dirty condenser
Have the error repaired by a
Wacker Neuson service center
--
Not enough refrigerant in the
system
Malfunctioning or insuffi-
ciently tightened V-belt
Dirty condenser
Clean the condenser
Temperature controller set to
heating
Set temperature controller to
ventilation
No or insufficient heating output
Very dirty condenser
Have the error repaired by a
Wacker Neuson service center
--
Malfunctioning thermostat
Temperature controller set to
ventilation
Set temperature controller to
heating
Loss of refrigerant
Loose hose connection
Have the error repaired by a
Wacker Neuson service center
--
Leak in system
Very loud system
Malfunctioning or insuffi-
ciently tightened V-belt
Have the error repaired by a
Wacker Neuson service center
--
Damaged air conditioning
compressor
Damaged fan motor
Summary of Contents for EZ38
Page 12: ...1 6 OM EZ38 us 1 1 ez38v100 fm 1 Notes ...
Page 38: ...3 10 OM EZ38 us 1 1 ez38e300 fm 3 Warning labels Fig 13 ...
Page 43: ...OM EZ38 us 1 1 ez38e300 fm 3 15 3 Labels Fig 29 ...
Page 156: ...5 60 OM EZ38 us 1 1 ez38b510 fm 5 Notes ...
Page 244: ...9 24 OM EZ38 us 1 1 ez38t900 fm 9 Dimensions Overview EZ38 ...
Page 246: ...9 26 OM EZ38 us 1 1 ez38t900 fm 9 Overview EZ38 VDS ...