6
TEBS E
GIO functions
66
Component /
Part number
Application /
Vehicle type
Purpose/Function
Comment
Connecting cable
ECAS solenoid valve
472 880 001 0
472 880 070 0 (Multi-
Voltage)
Semitrailer/Central axle
trailer (support bellows
of the axle(s) are not
connected to one an-
other) (without lifting
axle)
Drawbar trailer (sup-
port bellows of the
axles are respectively
connected to one an-
other)
2-point control of the
vehicle sides or control
of front and rear axle of
a drawbar trailer
2 point control with
version TEBS E2 or
higher
‘ECAS 2-point control’
cable
449 439 ... 0
ECAS solenoid valve
472 905 114 0
Semitrailer / Central
axle trailer with lifting
axle / rear axle
Drawbar trailer with
lifting axle
1-point control
Control of the ride
height on one or multi-
ple axles on parallel
circuits (lifting/lowering)
Pulse-controlled lifting
axle
The front axle of a
drawbar trailer can be
additionally controlled
using a valve
472 880 030 0.
ECAS solenoid valve
cable
449 445 ... 0
ECAS solenoid valve
472 905 111 0
Semitrailer/Central axle
trailer with lifting axle
(support bellows of the
axle(s) are not con-
nected to one another)
/ Rear axle drawbar
trailer (without lifting
axle)
Drawbar trailer with
lifting axle (support
bellows of the axles are
respectively connected
to one another)
2-point control
Control of the ride
height on one or multi-
ple axles on parallel
circuits (lifting/lowering)
2 point control with
version TEBS E2 or
higher
Pulse-controlled lifting
axle
ECAS solenoid valve
cable
449 445 ... 0
‘ECAS 2-point control’
cable
449 439 ... 0
Height sensor
441 050 100 0
Semitrailer / Drawbar
trailer with air suspen-
sion
Normal level meas-
urement
Use only height sensor
441 050 100 0.
Cable for height sensor
449 811 ... 0
Lever
441 050 718 2
441 050 641 2
Attaching the height
sensor
Extending the height
sensor lever
Linkage
433 401 003 0
Connection to the axle