6
TEBS E
GIO functions
100
Parameter setting
If just one function is available (figure 1), parameters only need to be set for the
proximity switch.
If both functions are to be available (figure 2), two additional switch inputs are re-
quired so that both functions can be switched on and off separately.
The switches for this must be configured as follows:
Road finisher brake = proximity switch and separate switch. Both switches must be
closed here so that the road finisher function is actuated.
Unloading level switch = proximity switch and separate switch. Both switches must
be closed here so that the unloading level starts up.
Proximity switches available on the market can have differing switching thresholds
depending on the distance to the object to be registered.
WABCO suggests a value of 600 µA for this, for trouble free operation of the prox-
imity switches named above. The switching threshold for other switches can be set
as required.
The GIO slots to use are defined in
tab 11
,
connector
.