ER SERIES ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
F35613 (
September
2003)
Page 11 of 48
5.
Remove temperature probe from the element
head.
6.
Reverse procedure to install.
NOTE:
When installing, ensure grommet remains in
place when inserting temperature probe thru the
grommet in the element head.
7.
Check cooking control calibration as outlined in
COOKING CONTROL CALIBRATION under
SERVICE PROCEDURES AND
ADJUSTMENTS.
HIGH LIMIT THERMOSTAT
WARNING:
DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT
/ TAGOUT PROCEDURES. THERE
MAY BE MULTIPLE CIRCUITS. BE
SURE ALL CIRCUITS ARE
DISCONNECTED.
CAUTION: Do not sharply bend and kink the
capillary tube or damage may occur.
1.
Raise heating elements.
2.
Loosen clamps securing capillary tube and
bulb to element.
3.
Remove element head cover as outlined under
COVERS AND PANELS.
4.
Remove high limit from mounting bracket.
5.
Disconnect high limit lead wires.
6.
Remove grommet from the element head
assembly.
7.
Remove the bulb, capillary tube and high limit
from the element head assembly.
NOTE:
When installing, slide grommet onto
capillary tube then insert grommet into the capillary
tube thru hole in the element head.
8.
Reverse procedure to install.
Summary of Contents for ERC50
Page 35: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 35 of 48 ...
Page 37: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 37 of 48 ...
Page 45: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 45 of 48 NOTES ...
Page 46: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 46 of 48 NOTES ...
Page 47: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 47 of 48 NOTES ...