ER SERIES ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
F35613 (
September
2003)
Page 13 of 48
NOTE:
When installing high limit, route the capillary
tube and center the bulb between the clamps before
tightening.
3.
Remove element assembly clamps. Front
clamps stiffen and secure both elements
together. Rear clamps stiffen each individual
element.
4.
Remove element head cover as outlined under
COVERS AND PANELS.
5.
Disconnect heating element lead wires.
NOTE:
Each heating element assembly contains
three individual elements (six lead wire connections
total).
6.
Remove screws from heating element
mounting bracket and remove heating element.
7.
Reverse procedure to install.
LIFT ASSIST SPRINGS
WARNING:
DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT
/ TAGOUT PROCEDURES. THERE
MAY BE MULTIPLE CIRCUITS. BE
SURE ALL CIRCUITS ARE
DISCONNECTED.
1.
Remove rear door (access cover) as outlined
under COVERS AND PANELS.
2.
Raise heating elements and place 2x4 lumber
under them for support. Heating elements are
to remain upright.
3.
Loosen all eye bolt mounting nuts to release
tension on springs.
Summary of Contents for ERC50
Page 35: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 35 of 48 ...
Page 37: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 37 of 48 ...
Page 45: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 45 of 48 NOTES ...
Page 46: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 46 of 48 NOTES ...
Page 47: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 47 of 48 NOTES ...