ER SERIES ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
F35613 (September 2003)
Page 10 of 48
3.
Lift the cooking control with mounting panel
attached, off the front control panel.
4.
Reverse procedure to install.
5.
Re-connect power and turn power switch on.
6.
Program the cooking control for the control
type as outlined under SOLID STATE
CONTROL or COMPUTER CONTROL in
SERVICE PROCEDURES AND
ADJUSTMENTS.
NOTE:
If installing a replacement cooking control,
program the control with the customers settings and
products.
7.
Check for proper operation.
FILTER VALVE AND DISCARD
VALVE SWITCHES
WARNING:
DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT
/ TAGOUT PROCEDURES. THERE
MAY BE MULTIPLE CIRCUITS. BE
SURE ALL CIRCUITS ARE
DISCONNECTED.
1.
Open the door to the fryer section being
serviced.
2.
Disconnect lead wire connector (2 pin) to the
switch.
3.
Remove switch mounting screws.
4.
Remove switch cover and disconnect lead
wires from switch.
5.
Reverse procedure to install and check for
proper operation.
NOTE:
Switches are not adjustable.
TEMPERATURE PROBE
WARNING:
DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT
/ TAGOUT PROCEDURES. THERE
MAY BE MULTIPLE CIRCUITS. BE
SURE ALL CIRCUITS ARE
DISCONNECTED.
CAUTION: Do not sharply bend and kink the
temperature probe or damage may occur.
1.
Raise heating elements.
2.
Remove clamps from temperature probe.
3.
Remove element head cover as outlined under
COVERS AND PANELS.
4.
Disconnect temperature probe lead wires.
Summary of Contents for ERC50
Page 35: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 35 of 48 ...
Page 37: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 37 of 48 ...
Page 45: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 45 of 48 NOTES ...
Page 46: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 46 of 48 NOTES ...
Page 47: ...ER SERIES ELECTRIC FRYERS TROUBLESHOOTING F35613 September 2003 Page 47 of 48 NOTES ...