ER SERIES ELECTRIC FRYERS - SERVICE PROCEDURES AND ADJUSTMENTS
F35613 (September 2003)
Page 20 of 48
SOLID STATE CONTROL
Operation
Refer to the Installation & Operations manual for
specific operating instructions.
Error messages
For information on solid state control error
messages, refer to SOLID STATE CONTROL under
TROUBLESHOOTING.
Programming
The solid state control’s programming mode is used
to set the controls operational parameters.
NOTE:
If a product key is active (timing),
programming mode can not be entered.
1.
Press V key to enter programming mode.
If the PARAMETER LOCK feature is disabled,
PROGRAM MODE entry is immediate. If the
PARAMETER LOCK feature is enabled LoC
will be displayed.
Use the following key sequence (password) to
enter PROGRAM MODE: LEFT BASKET/UP;
LEFT BASKET/UP; RIGHT BASKET/DOWN;
RIGHT BASKET/DOWN.
NOTE:
If the proper key sequence is not
entered within 6 seconds the control exits
PROGRAM MODE.
2.
Beeper chirp’s on each successful keypress; If
a key is not pressed within 2 minutes, the
control will automatically exit programming.
3.
To scroll through each of the PROGRAM
ITEMS, press V and release.
4.
To exit PROGRAM MODE, at any time, press
V and hold for 1 second.
PROGRAM
ITEM
KEY SEQUENCE
DISPLAY
5
Left Timer
• Press Left Basket to increase or Right Basket to
decrease cook time.
1
LED above left basket is on.
15:00
time value with flashing colon (MM:SS).
Right Timer
• Press Left Basket to increase or Right Basket to
decrease cook time.
1
LED above right basket is on.
15:00
time value with flashing colon (MM:SS).
Set point
Temperature
• Press Left Basket to increase or Right Basket to
decrease set point temperature.
2
340F
or 171C
current set point with flashing F or C
Calibration
Offset
• Press Left Basket to increase or Right Basket to
decrease offset temperature.
2, 3
00F
OR -00F
always in
/
F
Melt Options
• Press Left Basket or Right Basket to scroll thru
Melt Options.
CY L
CY L = Liquid
CY S = Solid
CY 0 = No
Energy Source
• Press Left Basket or Right Basket to select the
fryer
<
s energy source, electric or gas heat.
ELEC
or gAS
Parameter
Lock
• Press Left Basket or Right Basket to select
desired Parameter Lock Condition.
4
Uloc
or LoC
selected parameter is enabled if flashing
Degrees
F or C
• Press Left Basket or Right Basket to select
desired Temperature Scale.
F
or C
NOTES:
1. Time will change in one second increments, accelerating if the button is held.
2. Temperature will change in one degree increments, accelerating if the button is held.
3. Range -20 to +20, default = 0 (
/
F).
4. Selecting Parameter Lock enabled will take effect on the next Program Mode entry.
5. Default value shown in bold.
Summary of Contents for ERC50
Page 35: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 35 of 48 ...
Page 37: ...ER SERIES ELECTRIC FRYERS ELECTRICAL OPERATION F35613 September 2003 Page 37 of 48 ...