Page 1: ...ce and Assistance 24 For Sears warranty information or to contact a Sears Service Center call 1 800 4 MY HOME _ M 1 800 469 4663 IMPORTANT Read and follow all safety installation and operating instructions before first use of this product If you need SERVICE or PARTS for your Kenmore coin operated dryer When requesting service be ready to give the model number serial number located on a tag in the...

Page 2: ...explosion or to prevent property damage persona njury or death i Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance iWHAT TO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier fr...

Page 3: ...er or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint screen before or after each load Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and dirt The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel Do not place items ex...

Page 4: ...cted to the NEUTRAL white or center wire of the wiring harness at the terminal block Do not have a fuse in the neutral or grounding circuit Use a 4 wire conductor cord when the dryer is installed in an area where local codes do not permit grounding through the neutral If using a power supply cord Dryer power supply cord must be U h listed or CSA certified 120 240 volt minimum 30 amp Type SRD or SR...

Page 5: ...s do not permit the use of three wire connections Four wire Power Supply Cord For four wire installations the power supply cord must have four No 10 copper wires and match a four wire receptacle of NEMA Type 14 30R The fourth wire grounding conductor must be identified with a green cover or bare copper wire and the neutral conductor by a white cover 1 Disconnect power 2 Remove hold down screw and ...

Page 6: ... THESE INSTRUCTIONS The dryer can be connected directly to fused disconnect or circuit breaker box with four wire flexible armored or non metallic sheathed copper cable with grounding wire All current carrying wires must be insulated The grounding wire may be bare A conduit connector must be installed at junction box Allow four feet of slack in the line so dryer can be moved if servicing is ever n...

Page 7: ...rounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances For a permanently connected dryer This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grou...

Page 8: ...Hazard Use 10 gauge solid copper wire Use a UL approved strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to follow these in...

Page 9: ...mly 5 Tighten the strain relief screws 6 Insert tab of terminal block cover into slot of the dryer rear panel Secure cover with hold down screw 7 Connect separate copper grounding wire from external ground connector to an adequate ground If codes permit and a separate grounding wire is used it is recommended that a qualified electrician determine that the grounding path is adequate Neutral groundi...

Page 10: ...ATURAL GAS It is certified by CSA International for LR propane and butane gases with appropriate conversion No attempt shall be made to convert the appliance from the gas specified on the serial rating plate for use with a different gas without consulting the serving gas supplier Conversion must be done by a qualified service technician Gas conversion kit part numbers are listed on the gas valve b...

Page 11: ...ipe joint compounds that resist the action of L R gas must be used Do not use Teflon tape Important Observe all governing codes and ordinances A 120 volt 60 Hz AC only 15 or 20 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided If codes permit and a separate ground wire is ...

Page 12: ...n one section at a time until you reach the exhaust hood Use the hose attachment on your vacuum or a pole with a feather duster or rag attached to clean out lint Be sure the flapper on the outside end of vent moves freely When cleaning is complete be sure to follow these Installation Instructions for final product check Use duct tape to seal all joints Do not use screws to secure vent Lint may cat...

Page 13: ... from returning into the dryers and to keep the exhaust in balance within the main exhaust vent Unobstructed air openings are required Each exhaust vent should enter the main vent at an angle pointing in the direction of the airflow Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents The maximum angle of each vent entering the...

Page 14: ...le homes or sleeping quarters Contact your local building inspector Refer to the chart below for recommended installation requirements This will ensure you have an adequate clearance for service and proper operation including flow of combustion and ventilation air and that you have a sufficient distance from combustible construction Be sure your location allows for a proper exhaust installation Se...

Page 15: ...coin slide is set for 1 To change vend price follow instructions included with coin chute I 0 _ 0 0 Side View Closet 48 sq m J Closet door O Front View Control panel Mounting Screws 3 Insert the coin slide mechanism through the opening to the left of the control panel You may have to loosen four mounting screws for proper fit 4 Secure coin slide mechanism from inside control panel with _ inch coin...

Page 16: ... that all tools have been put away 6 Wipe each dryer drum thoroughly with a damp cloth Replacing nylon timing cams on accumulator mechanism Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock 1 Unplug dryer or disconnect power 2 Unlock control panel using a Phillips screwdriver Loosen two s...

Page 17: ...Ee 8 o IIIIIII Io DI IIII 25 I1_1111 35 DI IIII 5o II_DIII 6o DI Dill 75 IIDDDI 1 85 DIDDDI 1 oo I IllllllH I 1 1o DIllllllH I 1 25 IDDDDDI 1 35 DI Illlllllll 1 5o IDDDDDD 18o nlqlqlqlq 00 1 75 IBBBBBB 1 85 oOOOOOO 2 oo I0000000 7 Reassemble buffer 8 Pull slide back to original position and reassemble slide return spring NOTES Black slots are closed off by block out key To remove block out keys pu...

Page 18: ... location Drying Time The following charts are provided to give a general guideline on typical full loads and suggested times for these loads TYPICAL FULL LOAD The following chart gives examples of typical full loads LOAD TYPE INCLUDES LOAD TYPE INCLUDES Mixed 2 sheets Heavy 4 pairs jeans Load 4 pillow cases Work 4 pairs work 2 shirts Clothes pants 6 shorts 1 denim jacket 2 blouses 1 coverall 8 ha...

Page 19: ...roper RPM lint Lint screen Check lint screen for lint Exhaust vent Check exhaust vent for lint blockage Power supply Check line fuses and switches Gas burner Check for function Load Check for size and type of load Improperly grounded Check for control panel being grounded Drum will not rotate Drum belt Check for broken belt Be sure it is properly positioned on motor pulley Broken belt protector sw...

Page 20: ...RPM Odors Have you recently been painting staining or varnishing in the area where your dryer is located If so ventilate the area When the odors or fumes are gone from the area re wash and dry the clothing Is there a gas leak Turn offthe gas supply line leave your house and then call your local gas company If you need an additional parts list contact your nearest Sears Service Center or Parts Depa...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ...23 ...

Page 24: ...eed Call 6 a m 11 p m CST 7 days a week PartsDirect 1 800 366 PART 1 800 366 7278 www sears com partsdirect Para ordenar piezas con entrega a domicilio 1 800 659 7084 For the location of a Sears Service Center in your area Call 24 hours a day 7 days a week 1 800 488 1222 www sears com To purchase or inquire about a Sears Maintenance Agreement Call 7 a m 5 p m CST Monday Saturday 1 800 827 6655 SEA...