28
1.
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2.
FACTORY INSTALLED JUMPER. DO NOT REMOVE
3.
THE L TERMINAL IS SHOWN MONITORING AN OPTIONAL ALARM CONTACT. IF THE CONTACT CLOSES, THE
THERMOSTAT WILL DISPLAY “ES”, OVERRIDING THE ROOM TEMPERATURE DISPLAY.
4.
"O/B" TERMINAL MUST BE SET TO ENERGIZE AS EITHER "O" (FACTORY DEFAULT) OR "B" IN THE
INSTALLER SETUP.
Fig. 19. Typical wiring for a single-stage heat pump with auxiliary/backup heat (2H/1C
heat pump).SEE IMPORTANT NOTE ON PAGE 36 IF DUAL FUEL HEAT PUMP.