background image

1

6L

E

00

15

53

A

Product description

1

Context key for 

menu 

access 

2

Context key for mode access holidays 

3

Confirmation key 

OK

4

Adjustment keys 

+

and 

5

Indicator for days of the week

6

Automatic mode/manual mode
(thermostat without program)

7

Temperature settings adjustment

8

Standby 

9

Programming/program selection

A

Time and date adjustment

Z

Adjustment of settings

E

Ambient temperature

R

Heating indicator

T

Current setting    (

,  ,

Y

Temperature of current setting

U

Profile of today’s program

I

Current time

EK510

This programmable ambient thermostat has been designed to bring you comfort and energy economy.

It allows you to program and regulate your heating system at 3 temperature levels :

- Comfort 

: this is the temperature you desire during the hours you are present.

- Eco 

:

this is the temperature you desire during short absences or at night.

- Frost protection 

:

this is the guaranteed minimum temperature during your prolonged absences. 

It protects your accommodation against the dangers of frost.

Electrical installation and connections

To guarantee its ambient temperature-regulation

function, the thermostat should be installed around

1.3 m above the ground, on an interior wall and

away from direct sunlight or any heat source such

as a television, lamp, radiator, draft, chimney, etc.

Fix the thermostat onto the flush-mounted casing

or in the slot without a casing intended for this

purpose.

For optimum quality temperature regulation, seal

the flush-mounted casing or the electrical duct. 

1. Separate the product from the wall-mounted

base, by pushing on the button located under

the base.

2. Open the flap with the help of a screwdriver and

attach the wall-mounted base using the screws.

3. Next, pass the electrical cables into the holes

intended for this purpose.

This product must be installed

according to the local installation

standards in force.

TOP

+

ok

+

ok

2

2

1

1

2

2

 

 

TOP

TOP

1 2 3

1 2 3

4 - 5

N

 

L

2A

6A

Connection of a heat circulator

4. Connect the product according to the wiring

diagram below.

5. Reclose the flap

6. Clip the front face onto the wall-mounted

base.

 

 

   

   

   

 

 

 

input
from remote ambient thermostat

 

 

 

 

 

 

 

 

 

 

 

   

   

   

 

   

   

   

 

   

   

   

 

   

   

   

 

 

   

   

   

 

1 2 3

1 2 3

4 -  5

N

 

L

2A

   

   

   

 

   

   

   

 

   

   

   

 

Connection of the thermostat to a thermostat

input on the boiler

§

Programmable ambient

thermostat, mains, weekly ECO

User instructions

Reviews: