background image

3

www.hager.com

Programming

Four programs are available to program your

week : 

P1

P2

P3

which are pre-recorded and

not modifiable and 

P4

which is free and allows

you to create a personalised program that can

be different for each day of the week.

Assigning an existing program (P1, P2 or P3)

to one or more days of the week

You can assign any of the programs to all

7 days of the week, to a group of five week-

days, to a group of two days for the weekend

or to an individual day.

• Press key 

1

menu

to place the cursor

under 

prog

. The indicators for the seven

days of the week flash.

• Press key 

4

+

to select which day, or group

of days, to assign a program to.

Confirm using the 

OK 

key.

• 

P1

flashes. Press key 

4

+

to select the

program to apply.

Confirm using the 

OK

key.

As an example, to assign P2 to the group

of five weekdays and P1 to the group of two

weekend days :

• Press key 

1

menu

to place the cursor

under 

prog

. The indicators for the seven

days of the week flash.

• Press key 

4

+

to select to affect the group

of five days (the group of five days flashes).

Confirm using the 

OK 

key.

• 

P1

flashes. Press key 

4

+

to select

(

P2

flashes). Confirm using the 

OK 

key.

• Press key 

4

+

to select the group of

2 weekend days (the group of 2 weekend

days flashes).

Confirm using the 

OK 

key.

• 

P1

flashes. Confirm using the 

OK

key.

The thermostat returns to 

auto

mode.

P1

= Comfort temperature from 

06 :00

to 

23:00

Eco temperature from 

23:00 

to 

06:00

.

P1

is activated 7 days per week

by default. If this fits the rhythm of your

life then remain in automatic mode; if

not, continue.

P2

= Comfort temperature from

06:00 

to 

08:30 

and from 

16:30 

to 

23:00.

Eco temperature from

08:30 

to 

16:30 

and from 

23:00 

to 

06:00.

P3

= Comfort temperature from

06:00 

to 

08:30, 

from 

11:30 

to 

13:30

and from 

16:30 

to 

23:00. 

Eco temperature from

08:30 

to 

11:30, 

from 

13:30 

to 

16:30

and from 

23:00 

to 

06:00.

Creation of a personalised program P4 

This program allows you to adjust the heating

to suit your way of life. 

A 24-hour profile is composed of 48 points

(representing the set-points). You can visualise

the composition of your program at the bottom

of the display. 1 program step = 30 minutes.

Example : creating a program, 

P4

, for a group

of days (5 we 2 weekend days).

For the 5 weekdays, we would like 3 Comfort

periods from 06:00 to 08:00, from 12:00 to 14:00

and from 18:00 to 22:00.

For the two-week in days, we would like one

Comfort period from 08:00 to 22:00.

• Press key 

1

menu

to place the cursor under

prog

. The indicators for the seven days of the

week flash.

• Press key 

4

+

to select to affect the group of 

five days (the group of five days flashes). 

Confirm using the 

OK

key.

• P1 flashes. Press key 

4

+

to select P4 

(

P4

flashes). Confirm using the 

OK 

key.

• Press key 

1

until 6 :00 appears and key 

2

until 8:00 appears. Next press key 

1

until

12:00 and key 

2

until 14:00. Then press key

1

until 18:00 and finally key 

2

until 22:00. 

If you make an error, press key 

4

to move back

or key 

4

+

to advance and correct your program-

ming.

• Confirm using the 

OK 

key.

• The group of 2 weekend days flashes.

Confirm using the 

OK

key.

• 

P1

flashes. Press key 

4

+

to select P4

(

P4

flashes). Validez avec la touche 

OK

.

• Press key 

1

until 8:00 is reached and

then press key 

2

until 22:00.

Confirm using the 

OK

key.

Note :

The latest P4 program is held in memory and

automatically offered to be assigned to a new day

or group of days (whose P4 is empty).

Temporary override

By overriding until the next program step

In 

auto

mode, it is possible to modify the 

temperature of the current set-point.

• Press key 

4

+

or 

to increase or decrease

the displayed set-point temperature.

The set-point temperature flashes and the 

override is valid until the next program step. 

During the override period, the current set-point

temperature flashes.

What to do if... ?

There is no display :

check the connection to your thermostat.

30 min. in Eco

30 min. in Comfort

Technical characteristics

Power supply : 230V 

+10/-15%  50 Hz 

Power reserve : 4 hours

Static differential (On/Off regulation) : < 0.3 °C

Adjustment range

- Comfort temperature : 

+5 °C to +30 °C

- Eco temperature : 

+5 °C to +30 °C

Ambient temperature display range : 

0 °C à +40 °C

Operating temperature : 

0 °C to +45 °C

Storage temperature : 

-25 °C to +70 °C

Ball test temperature : 

75°C and 125°C

Clock operating accuracy : drifts < 1sec/day

Trip values : 250V max. 5A resistive/3A inductive

Minimum load excepted by the relay : 12V/10mA

Relative humidity : 90 % at 20°C

IP : 30

Ecodesign class: 4

IK : 04

Insulation class : II

Insulation type : 4 kV

Rigid cable cross-sections : 0,5 to 2.5 mm²

Flexible cable cross-sections : 0,5 to 1.5 mm²

Minimum pulse voltage : 4 kV

Pollution class : 3

Action type : 2B

Insulation type : reinforced insulation

Software structure : class A

Dimensions (l x h x d) : 97 x 138 x 30

Standards : NF EN 60730-1, NF EN 60730-2-1,

NF EN 60730-2-7, NF EN 60730-2-9,

NF EN 60730-2-11

EN 12098-2, EN 12098-5.

P4

= a free program which allows you to

create up to 5 Comfort temperature

periods and 5 Eco temperature periods,

for each of the days of the week.

Reviews: