The Tempo thermostat is designed to control the temperature of a
floor heating system for both 120-volt and 240-volt applications. The
thermostat can be used to control either the floor temperature or the
ambient temperature. It has a maximum load capacity of 15 A
(1800 W @ 120 VAC or 3600 W @ 240 VAC).

SUPPLIED PARTS

One (1) thermostat

One (1) floor temperature sensor

Four (4) solderless connectors

Two (2) 6-32 mounting screws

One (1) flat-tip screwdriver

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK. THE INSTALLATION MUST
BE PERFORMED BY A QUALIFIED ELECTRICIAN.

The thermostat’s housing is not watertight. Do NOT install the
thermostat in an area where it can be exposed to water or rain.

n

To remove the thermostat faceplate, loosen the screw at the 
bottom of the thermostat and lift the bottom of the faceplate 
outwards towards you.

o

Connect the thermostat wires to the power supply and to the load 
using solderless connectors for copper wires as shown below.

NOTE: All wires and connections must conform to the local electrical
code. This thermostat has tinned copper wires for line and load
connections. Special CO/ALR solderless connectors must be used if
these wires are to be connected to aluminium conductors.

p

Pull the temperature sensor wires through one of the openings 
on the thermostat base and connect the wires to terminals 1 and 
2 (no polarity).

The sensor cable must not come in contact with the
electrical wires and must be routed outside the electrical
box and follow the wall down to the floor.

Position the sensor cable such that it does not come in
contact with the floor heating wires. The sensor must be
centered between two floor heating wires for best
temperature control.

Do NOT staple the sensor head (the plastic end) to the floor.
Doing so might damage the sensor. Any damages might not
be noticeable during testing but can become apparent
several days later.

q

Push the excess length of the line voltage wires back inside the 
electrical box. Install the thermostat base onto the electrical box 
using the provided screws.

r

Set the DIP switches (refer to section 3).

n

Description

1.

o

Installation

2.

Backlight button 
(see section 4.3)

Temperature 
adjustment button

On/Off switch 
(see section 4.4)

Heating Intensity 
indicator 
(see section 4.2)

Temperature

Setpoint indicator 
(see section 4.1)

Ground fault indicator 
(see section 5)

Unoccupied mode 
indicator 
(see section 7.2)

GFCI test button/light

L2(N)

L1(L)

L2(N)

L1(L)

Load

Power supply

Red

Black

Red
(White)

Red

Black

Black

Black

240 V (120 V)

Red
(White)

Floor sensor

To remote control device (see section 7.2)

TEMPO

User Guide

Non-programmable Thermostat

400-114-019-A (Nuheat) ENG.fm  Page 1  Wednesday, November 5, 2008  9:24 AM