Nuheat TEMPO User Manual Download Page 3

Tempo

      400-114-019-A                    2008-11-05                    3/3

• If the 

TEST

 button illuminates, continue to step 4.

q

Switch the thermostat to Off then back to On.
• If the 

TEST

 button light goes off, 

the test has passed

. Set the

thermostat back to the desired temperature and ignore the
remaining steps. The test is now completed.

• If the 

TEST

 button light remains on, 

the test has failed

. Con-

tinue to step 5.

r

Switch the circuit breaker (at the service panel) of the heating 
system to off then back to on.

s

Repeat the test. If the test fails again, cut power to the heating 
system at the main electrical panel, have an electrician verify the 
installation and, if necessary, replace the thermostat.

The measured temperature is below the thermostat’s dis-
play range. Heating is activated.

The measured temperature is above the thermostat’s dis-
play range. Heating is deactivated.

Verify the thermostat and sensor connections.

7.1

Floor Limit Settings

You can set the minimum and maximum temperature that your floor
can reach. These settings are available only if the temperature
control mode setting is at 

AF

 (refer to section 3.2). 

NOTE: The desired ambient temperature might not be attainable if
the maximum floor temperature is set too low.

The thermostat generally turns heating On or Off to control the ambi-
ent temperature. However, if the floor temperature drops below the
set minimum floor temperature limit or rises above the maximum
limit, the thermostat will turn heating On or Off respectively, regard-
less of the ambient temperature, to maintain the floor temperature
within the desired limits.

The minimum and maximum floor temperature
limits are factory-set at 50 °F (10 °C) and 82 °F
(28 °C) respectively. To modify the limits, pro-
ceed as follows:

n

Switch the thermostat to Off.

o

While pressing any button, switch the thermostat back to On to 
access the floor temperature limit settings.

p

Press the Backlight button briefly to switch between minimum 
and maximum floor temperature settings.

q

Press the 

 buttons to set the desired limit.

r

Press the Backlight button for 3 seconds to save your modifica-
tions. After the data are saved, the thermostat displays the cur-
rent temperature or “– –”.

NOTE: Your modifications are automatically saved if no button is
pressed for 60 seconds.

7.2

Unoccupied Mode

The thermostat can be connected to any other remote control device
equipped with a dry contact. When the contact closes, the Unoccu-

pied Mode is activated and the Unoccupied Mode icon 

 

is dis-

played. In this mode, the thermostat lowers its setpoint by 7 °F (3.5
°C) and all temperature adjustments are blocked except for tempo-
rary bypass.

Temporary Bypass

You can temporarily bypass the Unoccupied Mode by pressing the

backlight button. During the bypass, the Unoccupied Mode icon 
flashes. The bypass is automatically cancelled after 2 hours or if the
backlight button is pressed again.

 

Display range  - F mode

: 32 °F to 140 °F (0 °C to 60 °C)

- AF mode

: 32 °F to 122 °F (0 °C to 50 °C)

Setpoint range  - F mode

: 40 °F to 104 °F (5 °C to 40 °C)

- A/AF mode

: 40 °F to 86 °F (5 °C to 30 °C)

Floor limit range (AF mode)

: 40 °F to 104 °F (5 °C to 40 °C)

Resolution

: ± 1.0 °F (0.5 °C)

Operating temperature

: 32 °F to 122 °F (0 °C to 50 °C)

Storage temperature

: -4 °F to 122 °F (-20 °C to 50 °C)

Control cycle

: 15 minutes

GFCI rating

: 5 mA

Certification

: c CSA us

NUHEAT INDUSTRIES THREE (3) YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a three-
year period following the initial date of purchase. During this period, 
NUHEAT will repair or replace, at our option and without charge, any 
defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to 
products poorly installed or randomly damaged before, during or after 
installation. This warranty cancels and replaces any other 
manufacturer's express or implied warranty as well as any other 
company commitment.
NUHEAT cannot be held liable for related or random damages 
before, during or after the installation of this product. The defective 
product as well as the purchase invoice must be returned to the place 
of purchase or mailed, prepaid and insured, to the following address:

s

Error Messages

6.

t

Advanced Operations

7.

v

Technical Specifications

8.

Supply

120 VAC, 60 Hz

240 VAC, 60 Hz

Maximum load

15 A (1800 W)

15 A (3600 W)

;

Warranty

9.

NUHEAT INDUSTRIES LTD.

USA

6920 Salashan Parkway
Building D-200
Ferndale, WA 98248

CANADA

1689 Cliveden Avenue
Delta, BC
V3M 6V5

1 (800) 778-9276

www.nuheat.com

NUHEAT

®

 is a registered trademark of Nuheat Industries LTD.

400-114-019-A (Nuheat) ENG.fm  Page 3  Wednesday, November 5, 2008  9:24 AM