40
User functions (password 013)
The user menu offers the following options: (you can select "YES/NO" for each).
Note: the system automatically manages any conflicts and overlaps between functions common to different modes,
enabling or disabling certain functions on a case by case basis. Example: when Holiday YES —> mode is activated, the
following are automatically set: Passive YES, Bypass NO, Act Prog NO.
BYPASS
Bypass function activation: in the summer, outside air that is
cooler than the inside air is directly introduced into the internal
environment without passing through the heat exchanger.
PASSIVE
Passive function activation: the heat pump is always off.
ACT PROG
Weekly programming activation: the saved programming (see
"SETUP") is activated.
HOLIDAY
Holiday mode activation: the device runs in Passive mode at
Night speed, bypass is always closed and weekly programming
is deactivated.
ALARM
This option allows you to manage all possible alarm messages. Multiple errors must be managed one by one, starting from
the first one that occurred. In these situations, an intermittent "Alarm!" signal will be emitted on the home screen or
intermittent messages "Alarm!", "Block!" and “OFF” will be displayed in the event of locking errors.
The possible alarm situations are:
Filters: non-locking error
Condensate drain: locking error
Temperature: non-locking error
In all cases, you can switch on the ALARM menu to view the necessary actions and reset errors. The various situations
that generate alarm signals are described below.
Filters
When the pre-set time period has elapsed, a non-locking alarm is displayed and filter replacement is required. The error
and counter can be reset after filter replacement (see "Maintenance and Cleaning").
ENGLISH
F
USE MENU
BYPASS
PASSIVE
ACT PROG
HOLIDAY
NO
NO
NO
NO
F
MAIN MENU
USE MENU
ALARM
SETUP
F
ALARM
REPLACE
FILTER.
RESET? YES