29
ENGLISH
Compliance with European Directives and Regulations
This equipment is a domestic/commercial use product in compliance with the following European Directives:
• Directive 2001/95/EC on general product safety
• Directive 2011/65/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(RoHS)
• Directive 2012/19/EC dangerous substances in electrical and electronic equipment (WEEE)
• Regulation (EC) No. 1907/2006 concerning the Registration, Evaluation, Authorization and Restriction of Chemicals
(REACH)
• Directive 2014/30/EU Electromagnetic Compatibility (EMC)
• Directive 2014/35/EU Low Voltage (LVD)
Limits of use
The product in question only serves the purposes indicated in paragraph “Description and use”. Set up connection to the
power supply as shown in paragraph “Electrical connetctions”.
PROHIBITED!: this product is not designed or intended to be used in hazardous environments (due to
potentially explosive atmospheres - ATEX or required IP higher than that of the device) or in applications
requiring security features (fault-tolerant, fail-safe) which can be life support systems and/or technologies
or any other context in which application malfunction can lead to death or injury to persons or animals or
to serious damage to property or the environment.
!
PLEASE NOTE!: if a possible fault or product failure can cause damage (to persons, animals or property),
a separate functional surveillance system with alarm functions is required to exclude such damage. It is
also necessary to prepare replacement operation!
!
1
11
13
12
18
19
9
8
10
16
15
14
2
3
22
4
5
6
7
21
6
17
Optional accessories
Equipment can be supplied with Remote control unit with wire connection LCD panel.
Code
Model
21.194
CB LCD R
21.195
CB LCD W
21.381
CB LCD D
Structure and equipment
Fig. 6
1. Ventilation air inlet flange (
Ø
125 mm)
2. Electronic control board
3. Electrical connection terminal board
4. Two-way valve
5. Heat pump compressor
6. Clean air delivery in room
7. Operator interface with LCD display
8. Outside air suction filter
9. High efficiency counter cross flow heat
exchanger
10. USB port
11. Condensate nebulisation to the outside
12. Stale air output flange (Ø 125 mm)
13. Automatic opening and closing damper
for air inlet in By-pass mode
14. Four-way valve
15. Upper heat pump exchanger
16. Centrifugal fans
17. Condensate discharge pump
18. Lower heat pump exchanger
19. Condensate collection tray
20. Stale room air inlet
21. Outside air filter housing
22. Stale air filter