Series S34 Instruction Manual
Appendix A Specifications
A-1
M-000-00030
Appendix A Product Specifications
Accuracy
≤1-inch Line Size: +/- 2% of rate
>1-inch Line Size: +/- 1% of rate
Accuracy is dependent on several variables including pipe characteristics and
transducer mounting configuration. Special calibration can improve accuracy.
Contact factory if needed.
Repeatability
+/- 0.2% of rate typical
Velocity: English Units: +/-.1 ft/sec of reading to +/-30 ft/sec
SI Units: +/- 0.03 m/s of reading to +/- 10.7 m/s
Pipe Sizes
Clamp-On Transducers:
2MHz
– 1/2” (15mm) to 6” (150mm)
1MHz
– 2” (50mm) to 20” (500mm)
0.5MHz
– 12” (300mm) to 200” (5000mm)
Installation conditions can affect transducer selection
Measurement Parameters
Volume Flow, Mass Flow, Density, Temperature, Energy Units
Temperature Range
Standard Temperature -4°F to 248°F (-20°C to 120°C)
Electronics Specifications
Power Supply
100 to 240 VAC, 50 to 60Hz
Battery Temperature
-4°F to 140°F (-20°C to +60°C)
Charging Temperature
32°F to 113°F (0°C to +45°C)
Display
Display
– 2x16 character LCD with backlight
Output Signals
Output Standard
– 2 analog 4-20mA, 2 alarms, 1 pulse output,
1 scaled frequency
Optional Output
– Energy output with the addition of optional temperature inputs
Fluid Types
Acoustically conductive fluids, including most clean fluids and many
liquids with entrained solids or gas bubbles. Some examples are:
Refined Hydrocarbons, Petroleum products, Crude oil, Hydraulic fluids,
Diesel and fuel oils, water, wastewater, Hot and chilled water, Glycol
water solutions, Other liquids.
Summary of Contents for SonoPro S34 Series
Page 34: ...Series S34 Instruction Manual Chapter 3 Operation 3 5 M 000 00030 Output Menu...
Page 69: ...Series S34 Instruction Manual Appendix A Specifications A 2 M 000 00030...
Page 73: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 2 M 000 00030 Pipe Chart...
Page 74: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 3 M 000 00030...
Page 75: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 4 M 000 00030...
Page 76: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 5 M 000 00030...
Page 77: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 6 M 000 00030...
Page 78: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 7 M 000 00030...
Page 79: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 8 M 000 00030...