Series S34 Instruction Manual
Chapter 3 Operation
3-15
M-000-00030
Diagnostics Menu
Use the Diagnostics Menu to evaluate signal integrity, simulate operation, and review the system
files. The system log files contain time/date stamped messages including power on, power off,
programming time outs, parameter faults, incorrect password entry, and other various information
relative to system operation and programming. See below for a description of the items in this
menu that evaluate signal integrity and simulate operation.
Spd Sound Ratio
, is a unitless measure between 0 and 1 that compares the
Fluid Temp 1
speed
of sound to the
TOF_Calc
speed of sound. The closer the value is to 1, the stronger the
correlation.
Signal Quality
, is a measure of the amplitude of the ultrasonic signal from 0 to 100%, that is
normalized for gain, fluid, and pipe materials. A value of 85% or higher is considered
acceptable. A value below 85% is considered unacceptable and Chapter 6 of the manual should
be referenced for steps on how to troubleshoot the application.
Sim Flow
, is an input used for testing the meter to verify that the programming is correct.
Simulated Flow allows you to enter a flow rate, and in turn, the meter will update all analog
outputs. The meter will output these new values and will use them to calculate a new density for
mass flow measurement. Note: when your diagnostic work is complete, make sure to return the
value to zero to allow the electronics to use the actual transducer values.
Summary of Contents for SonoPro S34 Series
Page 34: ...Series S34 Instruction Manual Chapter 3 Operation 3 5 M 000 00030 Output Menu...
Page 69: ...Series S34 Instruction Manual Appendix A Specifications A 2 M 000 00030...
Page 73: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 2 M 000 00030 Pipe Chart...
Page 74: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 3 M 000 00030...
Page 75: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 4 M 000 00030...
Page 76: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 5 M 000 00030...
Page 77: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 6 M 000 00030...
Page 78: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 7 M 000 00030...
Page 79: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 8 M 000 00030...