Hydraulic max. flow for X3 (optional
equipment)
The hydraulic maximum flow for X3 screen appears
when pressing arrow-down five times from the main
screen.
The setting mode screen for hydraulic maximum
flow for X3 appears when pressing the SELECT
button from the X3 screen.
Select the hydraulic max. flow for X3 setting for
both directions (symmetrical), left side or right
side (non symmetrical) and press SELECT to
adjust the maximum flow with the arrow buttons.
Use arrow-up for increasing and arrow-down for
decreasing the maximum flow. Each bar on the
graph corresponds approximately 12.5% of
maximum flow.
Select the characteristics of the X3 mode in the
mode menu by choosing between active, normal
and soft mode.
Active mode: Max. flow is activated without ramp
up.
Normal mode: Max. flow is activated with small
ramp up.
Soft mode: Max. flow is activated with slow ramp
up.
Press the SELECT button to save the setting or
press ESC to escape without saving.
See X3 setup page
43
to save the settings on the
keypad.
NOTE!
Use the proportional switch on the left control lever
to check the actual hydraulic flow or speed of the
tool.
NOTE!
It is possible to adjust the maximum flow for X3 with
the proportional switch on the lever, see page
48
.
V1138811
V1138812
34
Instrument panels
Display unit